General Bell Box Wiring

As with the detector wiring we would suggest that you adopt a standard for your Bell Box wiring,
the colour scheme below is provided as a suggestion only.

Hold Off Supply +................. Red

Hold Off Supply - .............. .. Black

Trigger................................... Blue

Tamper Return...................... Yellow

Strobe +................................ Green

Strobe -................................. White

Bell Tamper Ring

It should be noted that many bell boxes that are fitted with rechargable batteries will sound when
the battery is connected. This connection may take the form of manually connecting the battery
wires to terminals or placing a link into the On position. Depending on the bell box being used,
the sounder may sound when the battery is connected unless power from the control panel is
connected or the bell box tamper is closed or in some cases both. Most bell boxes produce
high volume noise adequate ear protection MUST be used.

Sample Bell Box Connections

Below is shown general and sample bell box connections for some of the popular bell boxes that
are available.

P

P

P

P

a

a

a

a

g

g

g

g

e

e

e

e

6

6

6

6

Bell +

Bell -

Bell Hold -

SAB TMP

Strobe +

Strobe -

Tamper Return

Supply -

Bell Trigger

Supply +

Strobe -

Strobe +

Control

panel terminals

General bellbox

connections

Check bellbox

terminal positions

Tamper Feed

Bell +

Bell -

Bell Hold -

SAB TMP

Strobe -

TMPR

12v

S-

0V

ST-

Control

panel terminals

XS3D / XS7

bellbox connections

Check bellbox

terminal positions

Bell +

Bell -

Bell Hold -

SAB TMP

Strobe -

R-TMP

0V

S-

12V+

ST-

Control

panel terminals

Delta E, Novagard 1E & 6

bellbox connections

Check bellbox

terminal positions

TMP-F

Bell +

Bell -

Bell Hold -

SAB TMP

Strobe +

Strobe -

R Tamper Return

-12v Supply

Bell SW-

+12v Supply

Strobe -

Strobe +

Control

panel terminals

Novagard 2&4

bellbox connections

Check bellbox

terminal positions

F Tamper Feed

Fig.6A

Fig.6B

Fig.6C

Fig.6D