background image

TMA4882-27 021910

B-11

B.38

STATus:QUEStionable:INSTrument:ISUM? QUERY

STAT:QUES:INST:ISUM?

Syntax:

Short Form: STAT:QUES:INST:ISUM? Long Form: STATus:QUESionable:INSTrument:ISUM?
Return Value: <int_value> actual register value

Description: Reads ISUM Register (see Table B-3). Unit returns value of ISUM Register for selected channel This

register is identical in function to the QUEStionable register for the selected channel

STAT:QUES:INST:ISUM:ENAB

B.39

STATus:QUEStionable:INSTrument:ISUM:ENABle COMMAND

Syntax:

Short Form: STAT:QUES:INST:ISUM:ENAB <int_value>
Long Form: STATus:QUESionable:INSTrument:ISUM:ENABle <int_value>

Description: Programs Questionable Instrument ISUM Enable Register (see Table B-3).The Questionable

Instrument ISUM Enable Register is a mask which determines which conditions are allowed to set the
Questionable Instrument ISUM Register for the selected channel.

STAT:QUES:INST:ISUM:ENAB?

B.40

STATus:QUEStionable:INSTrument:ISUM:ENABle? QUERY

Syntax:

Short Form: STAT:QUES:INST:ISUM:ENAB?
Long Form: STATus:QUESionable:INSTrument:ISUM:ENABle?
Return Value: <int_value> actual register value

Description: Reads ISUM Enable Register (see Table B-3). Unit returns value of ISUM Enable Register for

selected channel.

B.41 SYSTem:COMMunication:GPIB:ADDRess COMMAND

SYST:COMM:GPIB:ADDR

Syntax:

Short Form: SYST:COMM:GPIB:ADDR<INT VAL> 1 to 30
Long Form: SYSTem:COMMunication:GPIB:ADDRess<INT VAL> 1 to 30

Description: Sets selected power supply GPIB address.

B.42 SYSTem:COMMunication:SERial:BAUD COMMAND

SYST:COMM:SER:BAUD

Syntax:

Short Form: SYST:COMM:SER:BAUD {19200 | 9600 | 4800 | 2400}
Long Form: SYSTem:COMMunication:SERial:BAUD {19200 | 9600 | 4800 | 2400}

Description: Sets the unit to operate at the specified baud rate.

B.43 SYSTem:COMMunication:SERial:ECHO COMMAND

SYST:COMM:SER:ECHO

Syntax:

Short Form: SYST:COMM:SER:ECHO {ON | OFF}
Long Form: SYSTem:COMMunication:SERial:ECHO {ON | OFF}

Description: Enables (ON) or disables (OFF) echo mode (see PAR. 3.5.3.3) Sending ON causes all subsequent

characters to be echoed back. Sending OFF turns off the character echo after the nest line terminator
character. The *RST command has no effect on echo status

B.44 SYSTem:COMMunication:SERial:PACE COMMAND

SYST:COMM:SER:PACE

Syntax:

Short Form: SYST:COMM:SER:PACE {NONE | XON}
Long Form: SYSTem:COMMunication:SERial:PACE {NONE | XON}

Description: Enables (XON) or disables (NONE) data flow control via the serial interface (see PAR. 3.5.3.3)

B.45 SYSTem:COMMunication:SERial:PROMPT COMMAND

SYST:COMM:SER:PROM

Syntax:

Short Form: SYST:COMM:SER:PROM {ON | OFF}
Long Form: SYSTem:COMMunication:SERial:PROMpt {ON | OFF}

Description: Enables (ON) or disables (OFF) prompt (see PAR. 3.5.3.3). Sending ON causes the unit to return >

character after the command is parsed.

Advertising