5.3.

BASIC SETTING: RECORDER CONFIG

This option allows you to check and eventually modify the recording parameters and the
selected parameters (up to a maximum of 64). The calculation of the selected values is not
affected by the rotary switch position. If the number of selected values exceeds 64 the
message "

too many param

" will be displayed. The MENU mode is divided into 4 separate

sub-pages:

 1

st

page:

This page allows you to set the START/ STOP mode (AUTO or
MANUAL), the START and STOP time if AUTO mode is selected, the
Integration Period value, the Enabling/Disabling of voltage Sag and
Surge detection, the Enabling/Disabling of Harmonics detection. Press
ENTER to confirm the settings and pass to the following page.
Press ESC to leave the Menu without modifying the existing parameters.

 2

nd

page:

This page is devoted to the settings relevant to the VOLTAGE recording.
Press ENTER to confirm the settings and pass to the following page.
Press ESC to leave this page without modifying the existing parameters.
From this page you can enter the sub-

page “Harmonics” which permits you to

select the voltage harmonics to be recorded.
Press ENTER

to confirm the settings and leave the “Menu Harmonics".

Press ESC to leave the "Menu Harmonics" without modifying the existing
parameters.

 3

rd

page:

This page is devoted to the settings relevant to the CURRENT recording.
Press ENTER to confirm the settings and pass to the following page.
Press ESC to leave this page without modifying the existing parameters.
From this page you can enter the sub-

page “Harmonics” which permits you to

select the current harmonics to be recorded.
Press ENTER

to confirm the settings and leave the “Menu Harmonics".

Press ESC to leave the "Menu Harmonics" without modifying the existing
parameters.

 4

th

page:

Menu composed of two sub-pages devoted to the selection of the
POWERS and ENERGIES to be recorded. From this page you can enter
the sub-

page “POWER” and “ENERGY” which permits you to select the

parameters to be recorded.
Selecting the active powers for the recording, the corresponding active
energies will be automatically selected.
Selecting the reactive powers for the recording, the corresponding reactive
energies will be selected.
Press ENTER to leave this page confirming the modifications made.
Press ESC to leave the "Menu" without modifying the existing parameters.


The various pages of the "RECORDER CONFIG" can be schematized as follows: