Dmiiis, En - 17 – Amprobe DM-111S Current-Data-Logger User Manual

Page 19

Advertising
background image

DMIIIS

EN - 17

Symbols

Description

Advised settings

START:MAN

The recording of all the selected parameters will start at 00
seconds after pressing START/STOP (see chapter 7).

STOP:MAN

The recording of all the selected parameters will be interrupted
manually by pressing START/STOP (see chapter 9).

START:AUTO

STOP:AUTO

The recording of all the selected values will be started /
interrupted at the set dates and times. In order to start the
recording the user will have to press START/STOP to set the
instrument in Stand-by mode until the start date and time
previously set (see chapter 7).

INT. PERIOD

The value of this parameter determines how many seconds
the values of all the selected parameters will be memorized
(see chapter 16.4.1). Available choices:
5sec, 10sec, 30sec, 1min, 2min 5min, 10min, 15min, 60min.

15min

HARM REC.

ON = the instrument will record the values of the selected

voltage and current harmonics corresponding to the
voltages and currents selected in the corresponding
pages “Voltage” and “Current”.

Example: If the following Parameters are selected:
a) Phase Voltage 1 and 2, Thd, Harmonics 1,3,5.
b) Phase Current 2 and 3, Thd, Harmonics 3,5,7.
The instrument will record:
a) The Phase Voltage 1 and 2, Thd and Harmonics 1,3,5

of the Phase Voltage 1 and 2 while it will not record
anything about Phase Voltage 3

b) The Phase Current 2 and 3, Thd and Harmonics 3,5,7

of the Phase Current 2 and 3 while it will not record
nothing about Phase Current 1

OFF = the instrument will not record any voltage or current

harmonic selected

ANOM REC.

ON = the Instrument will record Voltage Sag and Surge (see

paragraph 16.1)

OFF = the instrument will not record any voltage Sag and

Surge

V1, V2, V3

V12, V23 or V32,

V31

RMS value of the voltage of phase 1, phase 2, phase 3
respectively, values of the phase-to-phase voltages 1-2, 2-3 or
3-2 and 3-1.

Single phase: V1

3 wires V

12

V

32

V

31

4 wires V

1

, V

2

, V

3

Thd, DC, 01...49

Voltage Total Harmonic Distortion, DC Component, 01..49
Harmonics respectively

Thd,01,03,05,07

Vref

(only if ANOM. REC

flag has been set

ON)

RMS reference value for Voltage used in Voltage Anomalies
detection (Voltage Sag and Surge). The Reference is:
a) Voltage Phase to Neutral for Single Phase and 4 wires

three phase system

b) Voltage Phase to Phase for 3 wires three phase system

Single phase: 230V

3 wires: 400V

4 wires 230V

LIM+, LIM-

(only if ANOM. REC

flag has been set

ON)

High and Low Voltage Percent threshold used in Voltage
Anomalies detection (Voltage Sag and Surge).
Example: Three Phase System 4 wires.
Vref = 120, LIM+= 6%, LIM-=10% =>
High Lim = 127.2V, Low Lim = 108.0V
The Instrument will detect a voltage Anomalies if the RMS
Voltage Values (calculated every 10ms) beyond the above
calculated thresholds (see paragraph 16.1).

Single phase: 120V

3 wires: 480V

4 wires 277V

I1, I2, I3, IN

RMS value of the current of phase 1, phase 2, phase 3 and of
the neutral respectively.

Single phase: I1

3 wires: I1, I2, I3

4 wires I1, I2, I3, IN

Thd, DC, 01..49

Current Total Harmonic Distortion, DC Component, 01..49
Harmonics respectively

Thd,01,03,05,07