DMIIIS

EN - 13


1

st

Page of the RECORDER

CONFIG MENU







Example of 2

nd

page in single-

phase mode with ANOM flag

enabled

Example of 2

nd

page in “3

wires” three-phase mode with

ANOM flag enabled

Example of 2

nd

page in “4 wires”

three-phase mode with ANOM

flag enabled





Example of sub-page

"VOLTAGE HARMONICS"

RECORDER CONFIG

START

MANU

STOP

MANU

INT. PERIOD: 15min

HARM REC: ON

ANOM REC: ON

+

-

RECORDER CONFIG

VOLTAGE:

V1

HARM. REC:Pg (ON)

Vref P-N: 230V

LIM+: 06% (243.8V)

LIM-: 10% (207.0V)

+

-

RECORDER CONFIG

VOLTAGE REC:

V12

V32

V31

HARM. REC:Pg (ON)

Vref P-P: 400V

LIM+: 06% (424.0V)

LIM-: 10% (360.0V)

+

-

RECORDER CONFIG

VOLTAGE REC:

V1

V2

V3

V12 V32 V31

HARM. REC:Pg (ON)

Vref P-N: 230V

LIM+: 06% (243.8V)

LIM-: 10% (207.0V)

+

-

ENTER

RECORDER CONFIG

VOLTAGE HARMONICS

Thd

DC

01

02

03

04

05

06

07

08 09 10 11

12 13 14 15 16 17 18

19 20 21 22 23 24 25

26 27 28 29 30 31 32

33 34 35 36 37 38 39

40 41 42 43 44 45 46

47 48 49

+

-

Use the multifunction keys F1, F2
to position the cursor on the
desired word and use the

multifunction keys F3 / F4 to modify
the value.

Press ENTER to confirm and
proceed inside the Menu, keeping
the settings made.

Press ESC to leave the Menu
without modifying the existing
parameters.

Use the multifunction keys F1,
F2 to position the cursor on the

desired voltage harmonic and
use the multifunction keys F3 /
F4 to select / deselect (it’s

selected if highlighted in
black).
Press ENTER to confirm.

Press ESC to leave the Menu
without modifying the existing

settings.
The instrument will record the
values of the selected

harmonics corresponding to
the voltages selected in one of
the two pages of the Menu
previously illustrated.

ENTER

MENU

To Select MANUAL or AUTOMATIC
start/stop mode, place the cursor on

MANU or AUTO using the
multifunction key F1 or F2 and select
the desired mode using F3 or F4.

If you want to change Voltage Harm. Selection place the

cursor on the corresponding “Pg” symbol then Press F3

Use the multifunction keys F1, F2

to position the cursor on the
desired word and use the

multifunction keys F3 / F4 to select
/ deselect the desired parameter
(it’s selected if marked in black).

Press ENTER to confirm and leave
the Menu keeping the settings

made.
Press ESC to leave the Menu
without modifying the existing
parameters.

Advertising