315

❚❚ Other Flash Units

The following flash units can be used in non-TTL auto and
manual modes.

Flash unit

SB-80DX,
SB-28DX,

SB-28, SB-26,

SB-25, SB-24

SB-50DX

1

SB-30, SB-27

2

,

SB-22S, SB-22,

SB-20, SB-16B,

SB-15

SB-23,

SB-29

3

,

SB-21B

3

,

SB-29S

3

Flash mode

A

Non-TTL auto

M

Manual

G

Repeating flash

REAR Rear-curtain sync

4

1 Select mode P, S, A, or M, lower built-in flash, and use optional flash unit only.
2 Flash mode is automatically set to TTL and shutter-release is disabled. Set flash unit to A (non-

TTL auto flash).

3 Autofocus is available with AF-S VR Micro-Nikkor 105mm f/2.8G IF-ED and AF-S Micro NIKKOR

60mm f/2.8G ED lenses only.

4 Available when camera is used to select flash mode.

A

Metering

The metering areas for FV lock when using optional flash unit are as
follows:

Flash unit

Flash mode

Metered area

Stand-alone flash

unit

i-TTL

4-mm circle in center of frame

AA

Area metered by flash

exposure meter

Used with other flash

units (Advanced

Wireless Lighting)

i-TTL

Entire frame

AA

Area metered by flash

exposure meter

A (master flash)