7 timecode and sync, 1 tc port and tc cord – Kinefinity MAVO Edge 8K Digital Cinema Camera User Manual

Page 35

Advertising
background image

MAVO Edge 8K Operation Manual (KineOS 7.0)

©2021 Kinefinity Inc.

Page 35 / 61

3.7 TimeCode and SYNC

Timecode is one of the key features of cinema camera. The camera shows time
code in Live View and Playback state. Timecode is written into recorded clips.
For ProRes, the mov file contains a single timecode track.

The camera enables three types of timecodes:

Free run:

timecode runs all the time, no matter you are recording or

not. The timecode is embedded into recorded clips;

Record run:

timecode runs only when recording. We recommend to

set timecode to 00: 00: 00: 00 when a new project begins;

External TC:

the camera can use timecode from an external device like

Ambient NanoLockit as timecode of camera: using a special cable to

connect a timecode generator to the TC port, then set timecode

source as external in the menu.

To choose or reset the timecode, please follow the operation on the right.

3.7.1 TC port and TC cord

The TC port is 0B 5-pin push-pull socket. It is compatible with the ARRI
Alexa camera TC port for LTC IN and OUT.

Timecode generator based on Ambient timecode system, such as
NanoLockit, is also a 0B 5-pin socket. You can check the TC cord on the
Kinefinity official website
or contact [email protected].

In addition, the camera can output timecode to other devices: connect the
TC input port of the device to the TC output port of the camera by a special
TC cord.

NOTICE

When the camera is set to external timecode, the Jam TC input

mode is not supported.

Menu Operation

Set the TimeCode

[MENU

Settings

TimeCode]

Port Definition

1. GND

2. LTC IN

3,4. NC

5. LTC OUT

Advertising