3.7.2 External TC

There are three kinds of frame rates when using external TC: Project FPS,
Sensor FPS and External FPS of TC generator. Make sure that the Sensor FPS
is an integral multiple of the External FPS.

Timecode on UI will be green if the system is successfully connected. If there
is no external timecode feeding into the camera, it will automatically employ
the internal timecode of the camera and the indicator shows in yellow. If the
timecode blinks in green/red/yellow, you need to check if the following
situations exist:

Improper settings on the frame rates

Poor cable connection;

Power loss of external timecode device;

Special settings needed for the timecode device. For example,

NanoLockit TC output needs to be activated manually.

3.7.3 Beeper and SYNC

The beeper has two usages:

It makes a tone of 1KHz and 2KHz respectively when the camera is
triggered on/off record, to give a signal to the crew in the field. You
can disable the beeper by the operation on the right.

The tone of 1KHz and 2KHz at the beginning of the video and end of
the video can be recorded when the camera is triggered on/off
record, as pilot for post-workflow. Disable the function by the
operation on the right.

Menu Operation

Set Beeper

[MENU

SYNC

Beeper: on/off]

Menu Operation

Set recording of Beeper

[MENU

SYNC

Recording Beeper: on/off]