World class 3000, Instruction manual – Emerson ROSEMOUNT 3000 User Manual

Page 41

Advertising
background image

Instruction Manual

IB-106-300NH Rev. 4.3

May 2005

Rosemount Analytical Inc. A Division of Emerson Process Management

Installation 2-5

World Class 3000

NOTE:

ALL MASONRY STACK WORK AND JOINTS EXCEPT
ADAPTOR PLATE NOT FURNISHED BY ROSEMOUNT
ANALYTICAL.

INSTALLATION FOR MASONRY

WALL STACK CONSTRUCTION

INSTALLATION FOR METAL

WALL STACK OR DUCT

CONSTRUCTION

0.50 (13)

3.75 (95)

MIN DIA HOLE
IN WALL

STACK OR DUCT
METAL WALL

MTG HOLES
SHOWN ROTATED
45 OUT OF
TRUE POSITION

o

WELD OR BOLT ADAPTOR
PLATE TO METAL WALL
OF STACK OR DUCT.
JOINT MUST BE AIR TIGHT.

0.50 (13)

4.50 (114)

O.D. REF

PIPE 4.00 SCHED 40
PIPE SLEEVE (NOT
BY ROSEMOUNT

)

LENGTH BY CUSTOMER

ANALYTICAL

MASONRY
STACK WALL

OUTSIDE WALL

SURFACE

JOINT MUST

BE AIRTIGHT

MTG HOLES

SHOWN ROTATED

45 OUT OF

TRUE POSITION

o

FIELD WELD

PIPE TO

ADAPTOR PLATE

BOLT ADAPTOR

PLATE TO OUTSIDE

WALL SURFACE

NOTE:

DIMENSIONS IN INCHES WITH
MILLIMETERS IN PARENTHESES.

2.50 (63.5)

MIN DIA HOLE
IN WALL

STACK OR DUCT
METAL WALL

WELD OR BOLT ADAPTOR

PLATE TO METAL WALL

OF STACK OR DUCT.

JOINT MUST BE AIR TIGHT.

FIELD WELD
PIPE TO
ADAPTOR PLATE

3.50 (89)
O.D. REF

PIPE 3.00 SCHED 40
PIPE SLEEVE (NOT BY
ROSEMOUNT

) LENGTH

BY CUSTOMER

ANALYTICAL

MASONRY
STACK WALL

OUTSIDE WALL

SURFACE

JOINT MUST

BE AIRTIGHT

BOLT ADAPTOR

PLATE TO OUTSIDE

WALL SURFACE

37840004

Figure 2-1. Probe Installation (Sheet 4 of 5)

Advertising