Honeywell VISTA-20P User Manual

Page 47

Advertising
background image

A

01 Zn List

1

Zone List

(prompt appears

if zone list was selected)

01-08 = zone list; [

∗] to continue

Enter the desired zone list number associated with this output number.

NOTE: Do not use pager zone lists 09-12 in output definitions.

Enter the zone list event that will activate this output.

Enter Event

0 = restore; 1 = alarm;

Alarm

1

2 = fault; 3= trouble

NOTE: For alarm, fault, and trouble, an event on ANY zone in the list activates the output,
but ALL zones in the list must be restored before the output is restored.
Press [

✱] to continue and skip to the “Output Action” prompt.

B

01 Enter Zn type

Perimeter 03

Zone Type

(prompt appears

if zone type was selected)

Enter the desired zone type associated with this output number. See below for a list of
available zone types.
CHOICES FOR ZONE TYPES:

00 = Not Used

05 = Day/Night

12 = Monitor Zone

01 = Ent/Exit #1

06 = 24 Hr Silent

14 = Carbon Monoxide

02 = Ent/Exit #2

07 = 24 Hr Audible

16 = Fire w/verification

03 = Perimeter

08 = 24 Hr Aux

23 = No Alarm Response

04 = Interior Follower

09 = Fire

24 = Silent Burglary

10 = Interior w/Delay 77 = Keyswitch Zone

81 = AAV Monitor Zone

90-91 = Configurable

CHOICES FOR SYSTEM OPERATION:

20 = Arming–Stay

36 = **At Bell Timeout***

52 = Kissoff

21 = Arming–Away

38 = Chime

54 = Fire Zone Reset

22 = Disarming

39 = Any Fire Alarm

58 = Duress

31 = End of Exit Time

40 = Bypassing

60 = AAV

32 = Start of Entry Time 41 = **AC Power Failure

66 = Function Key†

33 = Any Burglary Alarm 42 = **System Battery Low 67 = Bell Fail

43 = Comm. Failure

68 = Telco Line Cut

78 = Keyswitch Red LED

79 = Keyswitch Green LED

** Use 0 (Any) for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.
† Use *57 Menu Mode to assign the function key (function “07”).

Note: In normal operation mode:
Code + # + 7 + NN Key Entry starts Device NN.
Code + # + 8 + NN Key Entry stops Device NN.

Enter the partition in which this zone type will occur.

01 Partition

0 = any partition; 1 = partition 1;

Any partition

0

2 = partition 2; 3 = common

Press [

✱] to continue and skip to the “Output Action” prompt.

C

01 Enter Zn No.

12

Zone Number

(prompt appears

if zone number was selected)

Enter the desired zone number associated with this output number.
Press [

✱] to continue.

Enter the zone event that will activate this output.

01 Enter Event

0 = restore; 1 = alarm/fault/trouble

Restore 0

Press [

✱] to continue to the “Output Action” prompt

01 Output Action

Close for 2 sec

1

Output Action

0 = off

4 = Change Device State

1 = Close for 2 seconds

5 = Duration 1 (see data field *177)

2 = Stay Closed

6 = Duration 2 (see data field *177)

3 = Pulse on & off (1 sec ON, 1 sec OFF)

Enter the desired device action as listed above. Press the [

✱] key to continue.

Menu Mode Programming

5-11