Honeywell VISTA-20P User Manual

Page 79

Advertising
background image

CLASS 2 PLUG-IN

TRANSFORMER

16.5V

A

C

, 25V

A

(e

.g.

ADEMCO No

. 1321).

(USE No

. 1321CN IN CANAD

A)

T

O

110V

A

C

UNSWITCHED

OUTLET (24HR)

–

+

THIS EQ

UIPMENT SHOULD BE INST

ALLED

IN A

CCORD

ANCE

WITH

THE NA

TIONAL

FIRE PR

O

TECTION ASSOCIA

T

ION'S

ST

AND

ARD 72, CHAPTER 2 (NA

T

IONAL

FIRE PR

O

T

ECTION ASSOCIA

TION,

BA

TTER

Y

-MARCH P

ARK, Q

U

INCY

,MA

02269).

PRINTED INFORMA

TION

DESCRIBING P

R

OPER INST

ALLA

TION,

OPERA

TION,

TESTING, MAINTENANCE,

E

V

A

C

U

A

T

IO

N

PLANNING AND REP

AIR

S

E

R

V

IC

E

I

S

T

O

BE

PR

O

V

IDED

WITH

THIS

EQ

UIPMENT

.

24-HR B

A

TTER

Y ST

ANDBY REQ

UIRED FOR

FIRE INST

ALLA

T

IONS.

USE 12V

, 17.2AH

B

A

TTER

Y FOR 600mA A

UX PO

WER.

SEE

INSTR

UCTIONS.

B

A

TTER

Y

CAP

A

C

ITY FOR EMERGENCY

B

URGLAR

Y ST

ANDBY USE A

T

LEAST 4 HRS

USE UL LISTED LIMITED ENERGY

CABLE FOR ALL CONNECTIONS

USE 1361X10

TRANSFORMER

INTERF

A

C

E

IN PLA

CE OF 1321 OR

1321CN

WHEN PO

WER LINE CARRIER

DEVICES ARE BEING USED

. (SEE

INSTR

UCTIONS FOR CONNECTIONS)

FOR COMPLETE

INFORMA

TION, SEE

INSTR

UCTIONS K5305-1V2

ALARM OUTPUT

10.5

13.8VDC

, 2A MAX.

(600mA MAX.

FOR UL

USA

GE, INCLUDING

A

UX PO

WER) STEAD

Y

FOR B

URGLAR

Y/P

ANIC

,

TEMPORAL PULSE

SOUNDING FOR FIRE.

CAN USE ADEMCO No

. 702

SIREN, OR 12V BELL).

SEE INSTR

UCTIONS

.

CHARGING V

O

LT

A

G

E

13.8VDC

. MAXIMUM

CHARGING CURRENT

650mA.

B

A

TTER

Y

12V

, 4AH

–

+

–

+

BLA

C

K

RED

SEALED LEAD-A

C

ID

TYPE.

BA

TTER

Y NORMALL

Y NEED NO

T BE

REPLA

CED FOR A

T

LEAST 3

YRS

.

T

O

DETERMINE

T

O

T

AL ST

ANDBY LO

AD

ON BA

TTER

Y

, ADD 100mA

T

O

T

O

T

AL OF

A

UX.

PO

WER OUTPUT AND REMO

TE

KEYP

AD CURRENTS

.

FL

YING LEADS

FOR BA

TTER

Y

CONNECTION

CONNECTION OF

THE FIRE ALARM

SIGNAL

T

O

A FIRE ALARM

HEADQ

U

A

R

TERS OR A CENTRAL ST

A

T

ION

SHALL BE PERMITTED ONL

Y

WITH

THE

PERMISSION OF

THE LOCAL A

UTHORITY

HA

VING JURISDICTION.

THE B

URGLAR

ALARM SIGNAL SHALL NO

T BE

CONNECTED

T

O

A POLICE EMERGENCY

NUMBER.

OPTIONAL

FOR UP TO

40 ADDITIONAL ZONES

( FROM EITHER OR BO

TH GROUPS)

BLK

RED

GRN

YEL

12

3

78

11

12

17

20

21

22

23

24

25

EAR

TH

GR

OUND

SEE

INSTR

UCTIONS

FOR PR

OPER

GR

OUNDING

TELEPHONE WIRING

(VIA RJ31X* J

A

CK AND DIRECT

CONNECT CORD)

*CA38A IN CANAD

A

DOC LO

AD NO

.:

3

BLACK:

KEYP AD GR

OUND (- ) RETURN

RED: KEYP

AD PWR (

+

)

GREEN: D

A TA

IN FROM KEYP

AD

YELLOW:

KEYP AD D

A TA

OUT

REMO

TE

KEYP

ADS

AND O

THER

ADDRESSABLE

DEVICES

(e

.g.

5800TM,

4285/4286,

LRR,

4219,

4229,

4204,

5881)

W

ARNING:

T

O

PREVENT RISK OF SHOCK,

DISCONNECT

TELEPHONE LINE A

T

TELCO

J

A

CK BEFORE SER

VICING

THIS UNIT

.

BLK

RED

GRN

YEL

T

O

TERM

4

T

O

TERM

5

T

O

TERM

6

T

O

TERM

7

BLK

RED

GRN

YEL

AND/OR

RING

(GRA

Y)

TIP

(GREEN)

RING

(RED)

INCOMING

PHONE LINE

HANDSET

ZONE 1

ZONE 2

HI

LO

HI

LO

ZONE 3

ZONE 4

HI

LO

HI

LO

ZONE 5

ZONE 6

HI

LO

HI

LO

ZONE 7

ZONE 8

HI

LO

HI

LO

MAXIMUM LOOP RESIST

ANCE:

(EA

CH ZONE) 300 OHMS (PLUS EOLR)

RESPONSE,

ZONES 1-8:

10, 350, OR 700 MSEC (PR

OGRAMMABLE)

8-PIN CONNECT

OR

USED FOR 1361X10

TRANSFORMER

CONNECTIONS AND FOR

ON-BO

ARD TRIGGERS

SEE INSTR

UCTIONS

.

78

(USE SA4120XM-1

CABLE)

TIP

(BR

O

WN)

}

}

THIS DEVICE COMPLIES

WITH P

A

R

T

15 OF FCC R

U

LES

.

OPERA

TION IS SUBJECT

T

O

THE FOLLO

WING

TW

O

CONDITIONS:

(1)

THIS DEVICE MA

Y NO

T CA

USE HARMFUL

INTERFERENCE, AND (2)

THIS DEVICE MUST A

CCEPT ANY

INTERFERENCE RECEIVED

, INCLUDING INTERFERENCE

THA

T

MA

Y CA

USE UNDESIRED OPERA

TION.

COMPLIES

WITH FCC R

U

LES

, P

A

R

T

68.

FCC REGISTRA

TION NO

. 5GB

U

SA-44003-AL-E

RINGER EQ

UIV

A

LENCE:

0.1B

.

WEEKL

Y

TESTING IS REQ

UIRED

T

O

ENSURE PR

OPER OPERA

TION OF

THIS

SYSTEM.

IN ADDITION,

THIS SYSTEM MUST BE CHECKED BY A Q

U

ALIFIED

TECHNICIAN A

T

LEAST ONCE EVER

Y

THREE (3)

YEARS.

CAN BE USED FOR 2-WIRE SMOKE DETECTORS

RED JUMPER

CUT FOR BELL SUPER

VISION.

ALSO

, CONNECT 2000 OHM

RESIST

OR DIRECTL

Y A

C

R

OSS

SOUNDER.

FOR CONNECTION OF OPTIONAL 4285 OR 4286

VIP

MODULES

T

O

PHONE

TERMINALS

, SEE INSTR

UCTIONS

.

NO

TE:

KEYP

AD (S)

CURRENT (IN

BO

TH

P

A

R

T

ITIONS)

AND ALL

O

THER DEVICES

DRA

WING

PO

WER FR

OM

TERMS 4 & 5

MUST BE

INCLUDED IN

A

UX CURRENT

DRAIN

CALCULA

TIONS

.

A

UX.

PO

WER

OUTPUT

10.5-13.8VDC

600mA MAX.

(500mA MAX.

FOR UL

INST

ALLA

TIONS)

ALL OUTPUTS

ARE PO

WER

LIMITED

.

–

+

}

2000

OHMS

EOLR

2000

OHMS

EOLR

2000

OHMS

EOLR

2000

OHMS

EOLR

2000

OHMS

EOLR

2000

OHMS

EOLR

2000

OHMS

EOLR

2000

OHMS

EOLR

SYNC

COM

D

ATA

TO

TRANS

.

GND

+12 AU

X

18

19

16

15

14

13

10

9

6

4

12

3

4

5

6

OUTPUT 18

(TRIG. 2)

OUTPUT 17

(TRIG. 1)

ALL DEVICES AND A

CCESSORIES

USED IN A CANADIAN INST

ALLA

TION

MUST BE LISTED FOR USE IN CANAD

A

B

A

TTER

Y FUSE

FOR REPLA

CEMENT

,

USE SAME

V

ALUE

(e

.g.

ADEMCO No

. 90-12)

3A

SET

RECEIVER

’S

DIP SWITCH

FOR DEVICE

ADDRESS

OF

“0

”.

SEE

INSTR

UCTIONS

.

SET UNIT

’S

DIP SWITCH

FOR DEVICE

ADDRESSES

7 - 15

SEE

INSTR

UCTIONS

.

MAXIMUM NUMBER OF 2-WIRE SMOKE DETECT

ORS ON ZONE 1 IS 16;

DETECT

ORS MUST HA

VE COMP

A

T

IBILITY IDENTIFIER AS "A".

ZONE

P

A

IRS

2 / 10

3 / 11

4 / 12

5 / 13

6 / 14

7 / 15

8 / 16

13

12

14

10

11

6.2k

ZONE 10

3k

ZONE 2

2k

2k

2k

ZONE 3

2k

2k

2k

ZONE 4

T

A

MPER

CONT

A

CTS

T

A

MPER

CONT

A

CTS

VISTA-20P ONL

Y

TYPICAL WIRING

FOR

ZONE DOUBLING

(VIST

A-20P ONL

Y)

TYPICAL WIRING

FOR

DOUBLE B

ALANCED ZONE

(VIST

A-20P ONL

Y)

REMO

TE KEYP

ADS

CAN USE 6150 OR 6160

KEYP

ADS

. LOCAL

PR

OGRAMMING

MUST BE DONE

WITH A

6139/6160, B

UT NEED NO

T

REMAIN IN

THE SYSTEM

(SET

T

O

ADDRESS 16).

PO

WER SHUTDO

WN NO

TE:

SYSTEM SHUTS DO

WN SENSOR

DETECTION PR

OCESSING IF

CONTR

OL'S V

O

LT

A

GE

DR

OPS

BELO

W 9.6V

.

5

BLK

4-WIRE SMOKE DETECT

OR CONNECTIONS

+

+

2000

OHMS

EOLR

HEAT

DETECTOR

RED

EOL

POWER

SUPERVISION

RELAY MODULE

A77-716B.

USE N.O.

CONTACT,

WHICH CLOSES

WHEN POWER

IS APPLIED.

VIOLET

AUX PWR

OUTPUT

TERMINALS

5

4

_

_

+

BLK

_

TO ZONE TERM. ( )

TO ZONE TERM. ( )

(ZONES 2 - 8 ONLY)

RELAY

CONTACT OPENS MOMENTARILY

UPON FIRE ALARM RESET

PROGRAM RELAY

AS ZONE TYPE 54

(FIRE ZONE RESET)

_

+

4-WIRE SMOKE

OR COMBUSTION

DETECTOR

N.C

.

N.O

.

TO OUTPUT 17

PROGRAM OUTPUT 17 FOR

"OUT NORM LOW" = YES IN

79 MENU MODE AND AS ZONE

TYPE 54 IN 80 MENU MODE

MAX. CURRENT = 100 mA

(UP TO 16 DETECTORS

PLUS EOL MODULE)

OR

ADEMCO No.

4219

WIRED EXP

ANSION MODULE

(8 ADD'L EOLR

WIRED ZONES)

-AND/OR-

ADEMCO No.

4229

WIRED EXP

ANSION/RELA

Y MODULE

(8 ADD'L EOLR

WIRED ZONES PLUS 2

OUTPUT RELA

YS)

-AND/OR-

ADEMCO No.

4204 RELA

Y MODULE

(4 OUTPUT RELA

YS)

ADEMCO 5881*

T

ype

RF RECEIVER

WIRELESS ZONES

*5882 IN CANAD

A

5881L:

UP

T

O

8

5881M:

UP

T

O

16

5881H:

UP

T

O

56

V20P_V15P-SOC-V5

ADEMCO VISTA-20P / VISTA-20PSIA SERIES / VISTA-15P / VISTA-15PSIA SERIES

SUMMARY OF CONNECTIONS

Figure 17. Summary of Connections

10-11

Advertising
This manual is related to the following products: