5800 series transmitter input loop identification, Compatible 5800 series transmitters table – Honeywell VISTA-20P User Manual

Page 67

Advertising
background image

5800 Series Transmitter Input Loop Identification

All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of the input
loops requires its own programming zone

(e.g., a 5804's four inputs require four programming zones).

5802MN

ENROLL AS

"UR" OR "RF"

LOOP

1

V20P-006-V0

5817

ENROLL AS "RF"

5890

ENROLL AS

"RF" OR "RM"

LOOP 1

5808

ENROLL AS "RF"

LOOP 1

5809

ENROLL AS "RF"

5850 (GBD)

ENROLL AS "RF"

(Green)

(Red)

(Yellow)

5 8 0 4 B D

ENROLL AS "BR"

LOOP 4
YOU MUST
ENROLL
THIS BUTTON

SET

HOUSE

CODE

LOOP 3

LOOP 1

LOOP 2

5804

ENROLL AS "BR"

ON

5816MN

ENROLL AS "RF"

LOOP 2
(REED)

5816

ENROLL AS "RF"

LOOP 1
(TERMINALS)

LOOP 2
(REED)

LOOP 3

(TERMINALS)

5819S (WHS & BRS)

ENROLL AS "RF"

LOOP 1
(INTERNAL
SHOCK
SENSOR

LOOP 2

(REED)

5 8 1 9

ENROLL AS "RF"

LOOP 2

(REED)

LOOP 3

(TERMINALS)

LOOP 1
(TERMINALS)

5 8 0 1

ENROLL AS

"UR" OR "RF"

LOOP 3

LOOP 1

LOOP 2

LOOP 4

YOU MUST

ENROLL

THIS

BUTTON

LOOP 1

LOOP 2

LOOP 4

YOU MUST

ENROLL

THIS

BUTTON

LOOP 3

LOOP

1

MOTION

LOOP 2
(AUX.
CENTER)

LOOP 1
(PRIMARY)

LOOP 3
(AUX.
RIGHT)

LOOP 1
(TERMINALS)

ALTERNATE

POSITION

FOR LOOP 2

OFF


NOTE
: For information on any transmitter not
shown, refer to the instructions accompanying
that transmitter for details regarding loop
numbers, etc.

UL NOTE: The following transmitters are

not intended for use in UL
installations:

5802MN,

5802MN2,

5804,

5804BD, 5814, 5816TEMP,
5819, 5819WHS & BRS, and
5850.


Compatible 5800 Series Transmitters Table

Model Product

Input

Type

Description

5801 Wireless

Panic

Transmitter

UR or RF

• Four pushbuttons, each with a unique input (loop) code.

• Programmable responses (e.g., Panic, Arm, Disarm, etc.)

5802 Pendant

(Personal

Emergency Transmitter)

BR Only

• Has single pushbutton.

• Usually programmed for response type of 24-Hr audible or 24-Hr

Silent (other zone responses are possible).

5802CP

Belt Clip (Personal
Emergency)

BR Only

Same as 5802.

5802MN Miniature

(Personal

Emergency Trans.)

UR or RF

Same as 5802.

5804 Wireless

Key

Transmitter

BR Only

• Has four pushbuttons, each with a unique input (loop) code.

• Programmable responses (e.g., Arm, Disarm, etc.)

5804BD Bi-Directional

Wireless Key

BR

• House ID must be set.

• Requires 5800TM Transmitter Module.

• Can indicate system status via its 2 LEDs and built-in sounder.

• Has four pushbuttons, each with a unique input (loop) code.

• Operates the system similarly to wired keypads.

5806
5807
5808

Wireless
Photoelectric Smoke
Detectors

RF

One-piece smoke detectors with a built-in transmitter.

5809 Heat

Detector

RF One-piece rate-of-rise heat detector with a built-in transmitter.

5816

5816MN

Door/Window
Transmitters

RF

Has two unique input (loop) codes: one for a wired closed circuit
contact loop; the other for its built-in reed switch (used with a
magnet).

5816TEMP

Low-Temp. Sensor

RF

Transmits a fault condition when temperature drops below 45°F.

8-3

Advertising
This manual is related to the following products: