Compatible devices – Honeywell VISTA-20P User Manual

Page 6

Advertising
background image

Compatible Devices

Device VISTA-20P

VISTA-15P

Notes

Addressable Keypads

8

8

6150 Fixed-Word Keypad, 6160 Alpha Keypad, 6150V
Fixed-Word Display Voice Keypad, 6160V Alpha
Display Voice Keypad, 6150RF Keypad/Transceiver

Touch Screen (AUI)
Devices

2

2

Touch Screen (AUI) devices are in addition to the 8
addressable keypads. E.g., Symphony, 6270

4219, 4229 Zone
Expander Modules

Up to 5 for

up to 40

exp. zones

Up to 2 for

up to 16

exp. zones

Zone numbers are predefined according to the device
addresses used. See Expander Module Addresses table
in Wiring section and set addresses accordingly.

5800 Series Wireless

Up to 40 RF

zones

Up to 26 RF

zones

Uses 5881/5883 Series Receivers/Transceivers.

Output relays and/or
Powerline Carrier
Devices (X-10 type)

Up to 16

Up to 8

Use any combination of 4204, 4229 and or Powerline
Carrier Devices.
Map output devices via *79 Menu mode.

On-Board Triggers

2

2

Can be used to reset 4-smoke detectors.

Output functions

Up to 48

Up to 24

Program output functions via *80 Menu mode.

4285/4286 Phone
Module

Partition 1

only

yes

Provides access to the system via on premises or off-
premises phones for arming, disarming, etc., plus
control of relay outputs and Powerline Carrier devices.

Audio Alarm
Verification

Using AAV

module

Using AAV

module

Use ADEMCO UVS or Eagle Model 1250; can be used
in conjunction with an output trigger to permit voice
dialog between an operator at the central station and
a person at the premises.

Alarm output

12VDC, 2

AMP output

12VDC, 2

AMP output

Can drive the compatible sounders; steady output for
burglary/panic, or temporal pulse (3 pulses – pause –
3 pulses – pause – 3 pulses. . .) for fire. Uses current
limiting circuitry for protection.

Auxiliary Power Output

See note.

See note

12VDC, 600 mA maximum; uses fuse for protection.

Backup Battery

See note.

See note.

Rechargeable (sealed lead-acid type) 12VDC, 4AH
minimum.

Long Range Radio

See note.

See note.

Primary telephone number messages can be reported
via ECP connection to various Long Range Radios
(check compatibility/availability of specific models)

AC Power Supply

See note.

See note.

Plug-in 120VAC transformer, ADEMCO 1321
(1321CN in Canada) or, if using Powerline Carrier
devices, ADEMCO 1361X10 Transformer Module

NOTE: All devices and accessories used in a Canadian installation must be Listed for use in Canada.

Important Installation Highlights (Installer Please Read)

• This system uses addressable keypads and Zone Expander Modules (see Table of Addresses in

Section 2. Mounting and Wiring – Wiring the Keypads and Other Addressable Devices).

• Keypads must be set for addresses 16-23 (first keypad is address 16, which is different from

previous controls) and programmed in data fields *190-*196.

• Zone Expander Modules must be set for specific addresses (07-11), based on the zone numbers used.
• 4204 Relay Modules must be set for specific addresses (12-15).
• This control will not power-up unless AC power is connected (will not power-up on battery alone).

However, once the system is powered up, it will operate on battery power in the event of AC loss.

• Relays have two programming menu modes: Use *79 Menu mode to map module addresses and

device (output) numbers. Use *80 Menu mode to define the output functions.

• This system supports programmable function keys. Use *57 Menu mode to define the function

keys.

• This system provides various paging features. Refer to the Programming Overview section for a

summary on pager programming.

Installation and Setup Guide

1-2