background image

Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08

21

4. Rear Vent - Vertical Termination - (continued)

Three Elbows

Figure 5.19

Three Elbows

Figure 5.20

H

1

H

2

H

3

V

1

Minimum

H

1

+ H

2

+ H

3

Maximum

*

*

*

8 ft.

2.4 m

6 ft.

1.8 m

*

*

*

9 ft.

2.7 m

7 ft.

2.1 m

*

*

*

10 ft.

3.1 m

8 ft.

2.4 m

*

*

*

10 ft.

3.1 m

8 ft.

2.4 m

V

1

+ H

1

+ H

2

+ H

3

= 40 ft. (12.2 m) Maximum

*No specifi c restrictions on this value EXCEPT

V

1

+ H

1

+ H

2

+ H

3

cannot exceed 40 ft. (12.2 m) Maximum

H

1

+ H

2

+ H

3

= 8 ft. (2.4 m) Maximum

INSTALLED

HORIZONTALLY

H

2

H

3

H

1

V

1

H

1

V

1

H

2

V

2

H

1

Maximum

V

1

Minimum

H

2

H

1

+ H

2

Maximum

2 ft.

610 mm

6 in.

152 mm

2 ft.

610 mm

4 ft.

1.2 m

3 ft.

914 mm

1 ft.

305 mm

4 ft.

1.2 m

7 ft.

2.1 m

5 ft.

1.5 m

2 ft.

610 mm

6 ft.

1.8 m

11 ft.

3.4 m

7 ft.

2.1 m

3 ft.

914 mm

8 ft.

2.4 m

15 ft.

4.6 m

8 ft

2.4 m

4 ft.

1.2 m

10 ft.

3.1 m

18 ft.

5.5 m

H

1

= 8 ft (2.4 m) Max. V

1

+ V

2

+ H

1

+ H

2

= 40 ft (12.2 m) Max.

H

1

+ H

2

= 20 ft (6.1 m) Max.