Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08

40

WHT

WHT

BLK

BLK

GRN wire
inside box

Copper
ground attached
to GRN screw with
GRN wire

14/2WG

Romex
Connector

If the box is being wired to a wall
mounted switch for use with a fan (See
Figure 10.5):

• The power supply for the appliance

must be brought into a switch box.

• The power can then be supplied from

the switch box to the appliance using
a minimum of 14-3 with ground wire.

• At the switch box connect the black

(hot) wire and red (switch leg) wire to
the wall switch as shown.

• At the appliance connect the black

(hot), white (neutral) and green
(ground) wires to the junction box as
shown.

• Add a 1/4 inch insulated female con-

nector to the red (switch leg) wire,
route it through the knockout in the
face of the junction box, and connect
to the top fan switch connector (1/4
inch male) as shown.

Red

Red

Black

Black

Green

Green

White

White

Red

Black

Green

White

SWITCH BOX

JUNCTION BOX

POWER

SUPP LY WIRE S

SWITCH

MINIMUM 14-3

A W G

WITH GROUND

Note: Do NOT wire 110
VAC to wall switch.

• Remove the screw attaching the junction box/re-

ceptacle to the outer shell, rotate the junction box
inward to disengage it from the outer shell (see
Figure 10.4).

• Pull the electrical wires from outside the appli-

ance through this opening into the valve compart-
ment.

• Feed the necessary length of wire through the

connector.

• Make all necessary wire connections to the junc-

tion box/receptacle and reassemble the junction
box/receptacle to the outer shell.

Figure 10.4 Junction Box Detail

Figure 10.5 Junction Box Wired to Wall Switch

E. Junction Box Installation

F. Wall Switch Installation for Fan (Optional)

Advertising