Warning, B. installing the non-combustible board, C. securing and leveling the appliance – Heat & Glo Fireplace 6000G-IPI User Manual

Page 26

Advertising
background image

Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08

26

Figure 7.6 Remove the insulation from the outer vent
pipe. For rear venting there is no insulation in the outer
vent pipe.

Figure 7.7 To attach the fi rst section of vent pipe, make
sure to use the fi berglass gasket in the manual bag to seal
between the fi rst vent component and the outer fi replace
wrap. Use 2 self tapping screws to secure the gasket to
the outer wrap.

Secure the fi rst section of venting to the fi replace by screw-
ing through the two straps left over from cutting the seal
cap strap in step 2.

Figure 7.8 Non-combustible Board

B. Installing the Non-combustible Board

The factory supplied non-combustible board spans the
distance from the top of the fi replace to the center of
the framing header. This board must be used. See
figure 7.8.

HEADER

HEADER

C. Securing and Leveling the Appliance

The diagram shows how to properly position, level, and
secure the appliance (see Figure 7.9). Nailing tabs are pro-
vided to secure the appliance to the framing members.

• Venting - refer to Vent Clearances and Framing (Section

6) for hole location.

• Place the appliance into position.

• Level the appliance from side to side and front to back.

• Shim the appliance as necessary. It is acceptable to use

wood shims.

• Bend out nailing tabs on each side.

• Keep nailing tabs fl ush with the framing.

• Secure the appliance to the framing by using nails or

screws through the nailing tabs.

Figure 7.11 Proper positioning, leveling and securing of an

appliance

NAILING TABS

(BOTH SIDES)

Fire Risk.

• ALWAYS maintain specifi ed
clearances around the appliance.

• Do NOT notch into the framing around the appliance spacers.

Failure to keep insulation, framing or other material away from
the appliance may cause fi re.

Note: Once appliance is setup for top or rear venting, it
CANNOT be changed at a later time.

Fire Risk.

Prevent contact with sagging, loose insulation.

Do NOT install against combustible materials

such as exposed insulation, plastic and insulation
backer.

WARNING

WARNING

Note: Once appliance is setup for top or rear venting, it
CANNOT be changed at a later time.