Warning, B. constructing the appliance chase, C. clearances – Heat & Glo Fireplace 6000G-IPI User Manual

Page 8

Advertising
background image

Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08

8

Figure 3.2 Clearances to Combustibles

G

I

H

E

F

J

Clearance to Combustibles

A

B

C

D

E

F

G

H

I

J

Rough

Opening

(Vent Pipe)

Rough

Opening

(Height)

Rough

Opening

(Depth)

Rough

Opening

(Width)

Clearance

to Ceiling

Combustible

Floor

Combustible

Flooring

Behind

Appliance

Sides of

Appliance

Front of

Appliance

Inches

10

38-1/2

22

42

26-5/8

0

0

1/2

1/2

36

Millimeters

254

978

559

1067

676

0

0

13

13

915

Fire Risk.

Construct chase to all clearance specifi cations

in manual.

Locate and install appliance to all clearance

specifi cations in manual.

B. Constructing the Appliance Chase

A chase is a vertical boxlike structure built to enclose the
gas appliance and/or its vent system. Vertical vents that
run on the outside of a building may be, but are not re-
quired to be, installed inside a chase.

Construction of the chase may vary with the type of build-
ing. These instructions are not substitutes for the require-
ments of local building codes. Local building codes MUST
be checked.

Chases should be constructed in the manner of all out-
side walls of the home to prevent cold air drafting prob-
lems. The chase should not break the outside building
envelope in any manner.

Walls, ceiling, base plate and cantilever fl oor of the chase
should be insulated. Vapor and air infi ltration barriers
should be installed in the chase as per regional codes for
the rest of the home. Additionally, in regions where cold
air infi ltration may be an issue, the inside surfaces may be
sheetrocked and taped for maximum air tightness.

To further prevent drafts, the wall shield and ceiling
fi restops should be caulked with high temperature caulk
to seal gaps. Gas line holes and other openings should
be caulked with high temp caulk or stuffed with unfaced

C. Clearances

Fire Risk.

Odor Risk.

Install appliance on hard metal or wood surfaces

extending full width and depth of appliance.

Do NOT install appliance directly on carpeting,

vinyl, tile or any combustible material other than
wood.

insulation. If the appliance is being installed on a cement
slab, a layer of plywood may be placed underneath to pre-
vent conducting cold up into the room.