IMAGETEAM™ 2020/4620 System Manual

Codabar Check Character

Codabar check characters are created using different “modulos.” You can
program the imager to read only Codabar bar codes with Modulo 16 check
characters.

Default = No Check Character.

No Check Character indicates that the imager reads and transmits bar code
data with or without a check character.

When Check Character is set to

Validate and Transmit, the imager will only read

Codabar bar codes printed with a check character, and will transmit this
character at the end of the scanned data.

When Check Character is set to

Validate, but Don’t Transmit, the unit will only

read Codabar bar codes printed

with a check character, but will not transmit the

check character with the scanned data.

* No Check Character

Validate Modulo 16

and Transmit

Validate Modulo 16, but

Don’t Transmit