Hand Held Products 4620 User Manual

Page 203

Advertising
background image

IMAGETEAM™ 2020/4620 System Manual

12 - 11

Scan Stand

Scan Stand Mode

TRGMOD4

4-6

Scan Stand Symbol

FNC3

4-6

Presentation Presentation

Mode

TRGMOD3

4-6

Presentation LED Timer

LEDs Off

TRGPCK0

4-7

*LEDs On

TRGPCK1

4-7

Presentation Sensitivity

Range 0-20 (*1)

TRGPMS##

4-7

Hands Free Time-Out

Range 0 - 300,000 ms

TRGPTO######

4-7

Reread Delay

Short (500 ms)

DLYRRD500

4-8

*Medium (750 ms)

DLYRR750

4-8

Long (1000 ms)

DLYRRD1000

4-8

Extra Long (2000 ms)

DLYRRD2000

4-8

User-Specified Reread
Delay

Range 0 - 30,000 ms

DLYRRD#####

4-8

LED Power Level

Off

PWRLDC0

4-9

Low (50%)

PWRLDC50

4-9

*High (100%)

PWRLDC100

4-9

Illumination Lights

*Lights On

SCNLED1

4-9

Lights Off

SCNLED0

4-9

Aimer Delay

200 milliseconds

SCNDLY200

4-10

400 milliseconds

SCNDLY400

4-10

*Off (no delay)

SCNDLY0

4-10

User-Specified Aimer
Delay

Range 0 - 4,000 ms

SCNDLY####

4-10

Aimer Mode

Off

SCNAIM0

4-11

*Concurrent

SCNAIM1

4-11

Interlaced

SCNAIM2

4-11

Selection

Setting

* Indicates default

Serial
Command

# Indicates a
numeric entry

Page