Rs-232 receiver time-out, Rs-232 handshaking – Hand Held Products 4620 User Manual

Page 48

Advertising
background image

2 - 18

IMAGETEAM™ 2020/4620 System Manual

RS-232 Receiver Time-Out

The unit stays awake to receive data until the RS-232 Receiver Time-Out
expires. A manual or serial trigger resets the time-out. When an RS-232
receiver is sleeping, a character may be sent to wake up the receiver and reset
the time-out. A transaction on the CTS line will also wake up the receiver. The
receiver takes 300 milliseconds to completely come up. Change the RS-232
receiver time-out by scanning the bar code below, then scanning digits from the
inside back cover of this manual, then scanning

Save. The range is 0 to 300

seconds.

Default = 0 seconds (no time-out - always on).

RS-232 Handshaking

RS-232 Handshaking allows control of data transmission from the imager using
software commands from the host device. CTS/RTS operates in mode 2. When
this feature is turned

Off, no data flow control is used. When Data Flow Control

is turned

On, the host device suspends transmission by sending the XOFF

character (DC3, hex 13) to the imager. To resume transmission, the host sends
the XON character (DC1, hex 11). Data transmission continues where it left off
when XOFF was sent.

Default = RTS/CTS, XON/XOFF and ACK/NAK Off.

RS-232 Receiver Time-Out

RTS/CTS On

* XON/OFF Off

* RTS/CTS Off

XON/XOFF On

ACK/NAK On

* ACK/NAK Off