Replacing the it2020-5b interface cable, Troubleshooting base, Replacing the it2020-5b interface cable: -2 – Hand Held Products 4620 User Manual

Page 226: Troubleshooting base -2, Changing the it4620 battery

Advertising
background image

14 - 2

IMAGETEAM™ 2020/4620 System Manual

Replacing the IT2020-5B Interface Cable:

1. Turn the power to the host system

OFF.

2. Disconnect the base’s cable from the

terminal or computer.

3. Turn the base upside down.

4. Pull the connector out while

maintaining pressure on the connector
release clip.

5. Replace with the new cable.

Insert the connector into the opening
and press firmly. The connector is
keyed to go in only one way, and will
click into place.

Changing the IT4620
Battery:

1. Remove the screw on the end

cap.

2. Remove the battery from the

handle.

3. Insert battery.

4. Replace end cap and screw.

Troubleshooting Base

Note: Please visit the Services

and Support section of our
website (

www.handheld.com

) to check for the latest software for both the

imager and the base.

If your base is not functioning properly, review the following troubleshooting
guidelines to try to isolate the problem.

Is the red LED on?

If the red LED isn’t illuminated, check that:

The power cable is connected properly and there is power at the power
source.

The host system power is on (if external power isn’t used).

Is the green LED on?

End Cap