Rs-232, Wand emulation plug & play, Rs-232 -2 wand emulation plug & play -2 – Hand Held Products 4620 User Manual

Page 32

Advertising
background image

2 - 2

IMAGETEAM™ 2020/4620 System Manual

RS-232

The RS-232 Interface bar code is used when connecting to the serial port of a
PC or terminal. The following RS-232 Interface bar code also programs a
carriage return (CR) and a line feed (LF) suffix, baud rate, and data format as
indicated below. It also changes the trigger mode to manual.

Wand Emulation Plug & Play

In Wand Emulation mode, the imager decodes the bar code then sends data in
the same format as a wand imager. The Code 39 Format converts all
symbologies to Code 39.

The Same Code Format transmits UPC, EAN, Code 128 and Interleaved 2 of 5
without any changes, but converts all other symbologies to Code 39.

The

Wand Emulation Plug & Play Code 39 Format bar code below sets the

terminal ID to 61. The

Wand Emulation Plug & Play Same Code Format bar

code sets the terminal ID to 64. These Plug & Play bar codes also set the
Transmission Rate to 25 inches per second, Output Polarity to black high, and
Idle State to high. (If you want to change the terminal ID

only, without changing

any other imager settings, please refer to

Introduction

on page 2-1.)

Option

Setting

Baud Rate

115200 bps

Data Format

8 data bits, no parity bit, 1 stop bit

RS-232 Interface

Wand Emulation

Plug & Play

Same Code

Wand Emulation

Plug & Play

(Code 39 Format)