Control board layout, Front, Rear – Hoshizaki REFRIGERATED PREP TABLE WITH RAISED RAIL 73168 User Manual

Page 16

Advertising
background image

16

Front

Display/Change
Rail Setpoint

"UP" Button

"DOWN" Button

"SERVICE USE ONLY" Button

"MANUAL DEFROST" button

LED on for
Negative Values

Cabinet Temperature,
Alarm Display, and
Service Menu

Rail Temperature,
Alarm Display, and
Service Menu

Display/Change
Cabinet Setpoint

Energy Saving Mode LED
(Not used this model)

2. Control Board Layout

K101 Connector
# 1, 3 Transformer 10V

Control Voltage (Dark Blue)

K361 Connector
# 1, 3 Rail Liquid Line

Solenoid Valve (RLLV)
# 1, 5 Cabinet Liquid Line
Solenoid Valve (CLLV)

K311 Connector
# 1, 2 Comp Control
Relay (Brown)
# 3, 4 Cabinet Evaporator
Fan Relay (Red)
# 5, 6 Defrost Heater
Relay (Orange)

Chip Revision

Board Part Number

Rear

K201 Connector
# 1, 2 Rail Switch (Yellow)
# 3, 4 Defrost Thermistor
(Orange. Not used, but must be in
place)
# 5, 6 Rail Thermistor (Black) (RTh)
# 7, 8 Rail Switch (Pink)

K151 Connector
# 1, 2 Condenser Thermistor
(Gray) (Clogged Filter
Thermistor)
# 3, 4 Defrost Thermistor (Orange)
(Cabinet) (DTh)
# 5, 6 Cabinet Thermistor (Black) (CTh)
# 7, 8 Service Jumper (White)

K341 Connector
# 1, 2 Rail Fan Relay (Orange)

Fuse 3A 125V