60

B. Maintenance

1. Rail Condensate Pan

The rail condensate pan collects condensate water from the rail. Empty the pan as often
as necessary depending on conditions. Clean the pan at least once a month with a
clean, damp sponge or cloth containing a neutral cleaner.

2. Air Filter

The plastic mesh air filter (located behind the front panel) removes dirt and dust from
the air, and keeps the condenser from getting clogged. As the filter gets clogged,
the unit's performance will be reduced. Check the filter at least twice a month. When
clogged, use warm water and a neutral cleaner to wash the filter. The filter can be
removed by opening the front panel and lifting the filter away from the condenser.

3. Condenser

Check the condenser once a year, and clean if required by following the steps below.
More frequent cleaning may be required depending on location.

WARNING

1. Before cleaning the condenser, move the power switch to the "OFF" position

and unplug the unit to prevent electric shock or injury by moving parts.

2. Before cleaning the condenser, move all foods into another clean refrigerator

or freezer.

3. Condenser fins are sharp. Use care when cleaning.

1) Remove and clean the air filter.
2) Use a brush attachment on a vacuum cleaner to gently clean the condenser fins. Do

not use too much force, otherwise the fins could be damaged.

3) Replace the air filter in its proper position.

4. Power Supply Connection

If the plug or power cord is damaged, contact a Hoshizaki Certified Service
Representative immediately and ask for repairs.

All other maintenance or service on this unit should be performed in accordance with
the Hoshizaki Service Manual by a qualified service technician.