Hoshizaki REFRIGERATED PREP TABLE WITH RAISED RAIL 73168 User Manual

Page 26

Advertising
background image

26

Alarm

Signal

Priority Problem

Reset, Corrections, and Adjustments

E7

6

High Condenser Temperature Alarm
(clogged filter)

Condenser temperature is outside of
normal operating temperature. 140°F
(60°C)

Turn the power off, then back on.

Condenser and/or air filter dirty. Fan motor not
turning. Possible restriction in refrigeration system.

Failure to take action when this alarm activates
could result in damage to the compressor.

E8

3

Defrost Thermistor Malfunction Alarm

Defrost thermistor shorted or open.

After replacing defrost thermistor, alarm resets.

E9

4

Condenser Thermistor Malfunction
Alarm

Condenser thermistor shorted or open.

After replacing condenser thermistor, alarm resets.

EA

2

EEPROM Write Alarm

Control board has failed.

After replacing control board, alarm resets.

ED

1

EEPROM Verification or Read Alarm

Control board has failed.

After replacing control board, alarm resets.