2. LED Lights and Audible Alarm Safeties

The "POWER OK" LED indicates proper control voltage and will remain on unless a
control voltage problem occurs. For further details, see "II.B. Sequence of Operation."

Sequence Step

LED

Energized

Components

Min.

Max.

Fill Cycle

WTRIN

WV

-

-

Ice Purge Cycle

GM

GM, EH

5 min.

5 min.

Freeze Cycle (with refill)

GM, COMP,
WTRIN* (refill),

GM, EH, PDS, Comp,
FMR,
WV* (refill)

-

*On until UF/S closes.
Alarm sounds after
90 sec.

1-in-1 Drain Cycle
(S1 dip switch 4 off)

FLUSH (Drain)
GM, COMP
(only if IS not
satisfied)

DV
Comp, GM, EH, PDS,
FMR (only if IS not
satisfied)

2 sec.

2 sec.

1-in-12 Drain Cycle
(S1 dip switch 4 on)

FLUSH (Drain) DV

10 min.

10 min.

The built-in alarm safeties shut down the unit.

No. of Beeps

(every 5 sec.)

Type of Alarm

Reset Options

1

Low Water Safety
UF/S open > 90 seconds after WV energized.

Automatic reset once water supply is restored
and UF/S closes.

2

Control Switch
In "DRAIN" position longer than 15 minutes.

Automatic reset once the control switch is
moved to the "ICE" position.

3

High-Pressure Switch: N/A on this model.

See "III.B.2. SRC-10H" for high-pressure
switch operation.

4

High-Pressure Switch: N/A on this model.

5

Freeze Timer
WV off > 30 minutes since last WV activation.

Manual reset. Turn power off and on again.

6

Low Voltage
(92VAC±5% or less)

"POWER OK" LED turns off if voltage
protection operates.
The control voltage safeties automatically
reset when voltage is corrected.

7

High Voltage
(147VAC±5% or more)

8

Gear Motor
GMPR contacts fail to close.

Manual reset. Turn power off and on again.

9

Infrared Sensor (S1 dip switch 7)
MBC actuator paddle engaged.

Manual reset. Turn power off and on again.

Legend:

DV–drain valve; EH–evaporator heater; FMR–fan motor-remote; GM–gear

motor;

IS–infrared sensor bin control; MBC–mechanical backup bin control;

PDS-pump-down solenoid valve; WV–inlet water valve