11) Wipe down the infrared sensor lens, (located on the bottom of the icemaker) with the

cleaning solution. Next, rinse the cleaning solution off of the infrared sensor lens with a
clean, damp cloth.

Infrared Sensor

Infrared Sensor
Housing

Lens

12) Replace the top panel in its correct position. Move the control switch to the "ICE"

position, then plug the unit back in. Move the power switch to the "ON" position, then
replace the front panel in its correct position. Make ice using the solution until the
icemaker stops making ice.

13) Remove the front panel, then move the power switch to the "OFF" position. Move the

control switch to the "DRAIN" position, then move the power switch back to the "ON"
position. Replace the front panel in its correct position.

14) Allow the water system to drain for 5 minutes.
15) Remove the front panel. Move the control switch to the "ICE" position, then replace the

front panel in its correct position.

16) Open the water supply line shut-off valve to supply water to the reservoir.
17) After the gear motor starts, remove the front panel. Move the power switch to the "OFF"

position. Move the control switch to the "DRAIN" position, then move the power switch
back to the "ON" position. Replace the front panel in its correct position.

18) Allow the water system to drain for 5 minutes.

Note: If you do not sanitize the unit, go to step 14 in "III.A.5. Sanitizing

Procedure - Final."

19) Remove the front panel. Move the power switch to the "OFF" position, then unplug the

unit from the electrical outlet. Close the water supply line shut-off valve.

3. Sanitizing Solution

IMPORTANT

For safety and maximum effectiveness, use the solution immediately after
dilution.

Dilute 2.5 fl. oz. (74 ml or 5 tbs) of a 5.25% sodium hypochlorite solution (chlorine bleach)
with 5 gal. (19 l) of warm water.

4. Sanitizing Procedure - Initial

1) Make sure the power switch is in the "OFF" position, the unit is unplugged from the

electrical outlet, and the water supply line shut-off valve is closed. Remove the panels.

2) Remove the strap connecting the spout to the chute assembly, then remove the spout.

Remove the rubber O-ring and nylon O-ring at the top of the cylinder and also remove
the packing and chute bracket between the spout and chute.