G) factory use (s1 dip switch 9 & 10) – Hoshizaki MODULAR CUBELET SERENITY SERIES FS-1022MLH-C User Manual
Page 21
Advertising
21
f) Mechanical Bin Control Shutdown Delay (S1 dip switch 8)
Factory set for normal operation. No adjustment is required. The shutdown delay is the
time between the mechanical bin control proximity switch opening and the control board
shutting off the icemaker.
S1 Dip Switch
Setting
Mechanical
Backup
Bin Control
Shutdown Delay
No. 8
OFF
0.25 Seconds
ON
6.7 Seconds
g) Factory Use (S1 Dip Switch 9 & 10)
Factory set for optimum performance. Do not adjust.