Fig. 10, Fig. 9 – Hoshizaki MODULAR CUBELET SERENITY SERIES FS-1022MLH-C User Manual

Page 52

Advertising
background image

52

7) Pour the cleaning solution over the extruding head until the evaporator assembly and

the reservoir are full and the solution starts to overflow into the drain pan.
Note: If there is excess scale on the extruding head, fill the evaporator assembly and

reservoir as described above, then use a clamp on the reservoir hose between
the reservoir and evaporator assembly to block flow. Pour additional cleaning
solution over the extruding head until the evaporator assembly is completely full.

8) Replace the spout and strap in their correct positions.
9) Allow the icemaker to sit for about 10 minutes before operation. If you placed a clamp on

the reservoir hose in step 7, remove it before operation.

10) In bad or severe water conditions, clean the float switch assembly as described below.

Otherwise, continue to step 11.

a. Remove the float switch assembly from the reservoir cover.
b. Wipe down the float switch assembly with the cleaning solution.
c. Rinse the float switch assembly thoroughly with clean water.
d. Replace the float switch assembly in its correct position.

Reservoir

Reservoir Cover

Float Switch Assembly

Fig. 10

5) Remove all of the ice from the dispenser unit/storage bin.
6) Remove the strap connecting the spout to the chute assembly, then remove the spout.

See Fig. 9.

Fig. 9

Strap

Spout

Chute

Rubber O-Ring

Packing

Proximity Switch

Packing

Ties
(Hook and Loop)

Chute Insulation

Baffle

Plate

Packing

Backup Bin Control Assembly Mount

Actuator

Shaft

Extruding Head

Evaporator Assembly

Nylon O-Ring

Reservoir

Chute
Bracket

Infrared Sensor Lens

Float Switch
Assembly

Reservoir Cover

Reservoir
Hose

Advertising