c) Drain Frequency Control (S1 dip switch 4)

This unit is factory set for optimum performance with the 1-in-1 drain cycle (S1 dip
switch 4 in the "OFF" position). This setting allows for removal of sediment from the
evaporator without interrupting the icemaking process. An optional 1-in-12 drain cycle is
available.

S1 Dip Switch Setting

Drain Timer Interval Drain Valve Open

No. 4

OFF (1-in-1)

1 Hour

2 Seconds

ON (1-in-12)

11 Hours 45 Minutes

10 Minutes

d) Continuous Dispensing Timer (S1 dip switch 5 & 6)

DCM models only. The dispense mode switch on DCMs must be in the "CONTINUOUS"
position for this setting to apply. The factory setting allows ice to be dispensed
continuously as long as the dispense solenoid is activated.

S1 Dip Switch Setting

Dispense Time

No. 5

No. 6

OFF

OFF

No Limit

ON

OFF

20 Seconds

OFF

ON

60 Seconds

ON

ON

No Limit

e) Bin Control Selector (S1 dip switch 7)

This unit is factory set for infrared sensor bin control operation. No adjustment is
required. When used on a standard ice storage bin, the mechanical bin control may be
used instead of the infrared sensor by moving S1 dip switch 7 to the off position. In the
factory default position (S1 dip switch 7 in the on position), the gear motor delay after the
upper float switch closes is 30 seconds. When the mechanical bin control is used (S1
dip switch 7 in the off position), the gear motor delay after the upper float switch closes is
5 seconds.

WARNING! Do not place S1 dip switch 7 in the off position on dispenser

unit applications.

S1 Dip Switch

Setting

Bin Control Application

Gear Motor Delay

No. 7

OFF

Mechanical Bin Control (Standard Ice Storage Bins Only)

5 seconds

ON

Infrared Sensor with
Mechanical Bin Control Backup

30 seconds