Mechanical backup bin control check, Fig. 3, Fig. 4 – Hoshizaki MODULAR CUBELET SERENITY SERIES FS-1022MLH-C User Manual

Page 34

Advertising
background image

34

Infrared Sensor

Infrared Sensor
Housing

Lens

Infrared Sensor LED

Infrared Sensor LED

Fig. 3

Thumbscrew

Fig. 4

Chute Assembly

Actuator Paddle

Spout

Strap

Proximity Switch

Strap

2. Mechanical Backup Bin Control Check

When the actuator paddle is not engaged MBC is closed and the icemaker produces ice.
a) Mechanical Backup Bin Control: S1 dip switch 7 placed in the "ON" position, MBC
is used as a backup bin control safety. When ice fills the chute and engages the actuator
paddle, MBC opens and CB shuts down the icemaker within 10 seconds and sounds a
9-beep alarm.
b) Stand-Alone Mechanical Bin Control: S1 dip switch 7 placed in the "OFF" position,
MBC is used as a stand-alone bin control. The stand-alone application should only be
used in Hoshizaki standard ice storage bin applications.

WARNING! Do not place S1

dip switch 7 in the "OFF" position on dispenser unit applications. When ice fills the
chute and engages the actuator paddle, MBC opens and CB shuts down the icemaker
within 10 seconds.

1) Remove the front panel.
2) Move the power switch to the "OFF" position, then unplug the unit from the electrical

outlet.

3) Remove the strap connecting the spout to the chute assembly. See Fig. 4. Pull up the

chute assembly slightly so that you can access the actuator paddle located in the top of
the chute.

4) Plug the unit into the electrical outlet.
5) Move the power switch to the "ON" position to start the automatic icemaking process.

9) Remove the object covering IS. If you removed IS housing from the base, replace it in

its correct position, and secure it with the thumbscrew.

10) Move the power switch to the "OFF" position. Unplug the icemaker from the electrical

outlet, then proceed to "IV.D.2. Mechanical Backup Bin Control Check."