Installation – Harman Stove Company PB 105 User Manual

Page 19

Advertising
background image

19

3-90-07205R19_05/13

Installation

* PRESSURE
RELIEF VALVE

* TEMPERATURE/PRESSURE
GAUGE

AIR VENT

TYPICAL BOILER HOT WATER PIPING SHOWING AIR REMOVAL SYSTEM, PROVISIONS FOR THE EXPANSION OF
WATER AND THE AUTOMATIC COLD WATER SUPPLY. ALSO SHOWN IS THE AUTOMATIC MIXING VALVE. THIS
COULD ALSO BE DONE BY (2) CLOSELY SPACED TEE'S. THE PROPER PIPING FOR THE INTENDED USE WILL BE
DETERMINED BY THE INSTALLING CERTIFIED PLUMBER OR HVAC CONTRACTOR.

UNION

SHUT-OFF
VALVE

* AQUASTAT
WELL

UNION

SYSTEM SUPPLY 1-1/4"

* ITEMS SUPPLIED

** OPTIONAL

PRESSURE REDUCING VALVE (PRV)
OR COMBINATION PRV AND
RELIEF VALVE

* BOILER DRAIN, 1/2" NPT MALE X
3/4" HOSE MALE (NOT SHOWN)

SENSING BULB

EXPANSION TANK
(DIAPHRAGM TYPE)

SHUT-OFF VALVE

PIPE TO WITHIN 6" OF THE
FLOOR OR A FLOOR DRAIN

SYSTEM RETURN 1-1/4"

** THERMOMETER

CHECK VALVE (OR BACKFLOW
PREVENTER IF REQUIRED)

** THERMOMETER

NOTE: ALWAYS REFER TO THE INDIVIDUAL COMPONENTS RECOMMENDED
INSTALLATION INSTRUCTIONS FOR THE PROPER MOUNTING POSITION AND
LOCATION WITHIN THE PIPING SYSTEM.

AIR SCOOP

AUTOMATIC
MIXING VALVE

COLD WATER
SUPPLY 1/2"

SYSTEM SUPPLY 1-1/4"

SHUT-OFF VALVE

NOTe: Cold return water temperature (Sustained temperatures below 140 degrees Fahrenheit) will lead to condensation in the firebox.

This moisture can lead to creosote formation. To help minimize moisture and creosote, it is strongly recommended that some form of

temperature balance is incorporated into the return water system.
NOTICe: When installing with the atmospheric conversion: All of the pressurized system components shown are not necessary. Air

vents or bleeders will need to be removed from the plumbing system to prevent air from entering the lines. Control Dipswitch #6 will need

to be turned “ON”.

*BOILER DRAIN, 3/4” NPT MALE X

3/4” HOSE MALE (NOT SHOWN)

Advertising