Maintenance – Harman Stove Company PB 105 User Manual

Page 32

Advertising
background image

32

3-90-07205R19_05/13

Maintenance

disposal of Ashes

Ashes should be placed in a steel container with

a tight fitting lid. The closed container of ashes

should be moved outdoors immediately and placed

on a non-combustible floor or on the ground, well

away from all combustible materials, pending final

disposal. If ashes are disposed of by burial in soil

or otherwise locally dispersed, they should be

retained in the closed container until all cinders

have thoroughly cooled. Other waste shall not be

placed in this container.
Soot and Flyash: Formation and Need for

Removal

The products of combustion will contain small

particles of flyash. The flyash will collect in the

exhaust venting system and restrict the flow of

the flue gases. Incomplete combustion, such

as occurs during startup, shutdown, or incorrect

operation of the room heater will lead to some soot

formation which will collect in the exhaust venting

system. The exhaust venting system should be

inspected at least twice monthly to determine if

cleaning is necessary. Pay particular attention to

screening in the vent cap. The screen, if present,

will accumulate with ashes rather quickly.

Fig. 21

Ash Door Handle

Ash Door

Ash Pan

Ash Pan Handle

WARNING! RISK OF FIRe!

• Ash, soot or creosote build-up may cause

overheating or fire.

• Routine cleaning of heat exchangers and

venting is required.

Ash Removal

It is recommended to remove the ashes when the

boiler is not in operation. This lessens the chances

of coming in contact with hot surfaces. Ashes can

be removed while in operation but, extra care must

be taken.
Open Ash door
Lift the latch and open the door as shown in fig. 21.
NOTE: Keep hopper lid, hopper swing plate,

firebox door and ash pan door closed during

operation and maintain all seals in good

condition.
Remove Ash Pan

Always wear gloves to remove ash pan. Grab the

ash pan by the finger hold and pull it out of the

boiler. Lift the ash pan by the finger hold and use

it for carrying the ash pan.

Close the ash door

before disposing the ashes.