Operation, Pellet boiler outdoor air reset operation – Harman Stove Company PB 105 User Manual

Page 26

Advertising
background image

26

3-90-07205R19_05/13

Operation

Pellet

Boiler

Outdoor

Air

Reset

Operation

When

the

outdoor

sensor

is

installed,

at

20°

F

. or

below

OA

T

(Outdoor

Air

Temperature),

the

boiler

will

operate

at

the

temperature

set

on

the

Maximum

Temperature

knob.

The

boiler

water

temperature

will

decrease

by

1

degree

for

every

1

degree

in

temperature

rise

of

the

Outside

Air

.

Example

1

OA

T

W

ater

T

emp

Degree

Change

Max

set

at

185

o

65

o

140

o

-45°

Min

set

at

140

o

60

o

145

o

-40°

55

o

150

o

-35°

50

o

155

o

-30°

45

o

160

o

-25

o

40

o

165

o

-20

o

35

o

170

o

-15

o

30

o

175

o

-10

o

25

o

180

o

-5

o

20

o

185

o

0

o

15

o

185

o

0

o

10

o

185

o

0

o

5

o

185

o

0

o

185

o

Example

2

OA

T

W

ater

T

emp

Degree

Change

Max

set

at

180

o

65

o

150

o

*

Min

set

at

150

o

60

o

150

o

*

55

o

150

o

*

50

o

150

o

-30

o

45

o

155

o

-25

o

40

o

160

o

-20

o

35

o

165

o

-15

o

30

o

170

o

-10

o

25

o

175

o

-5

o

20

o

180

o

0

o

15

o

180

o

0

o

10

o

180

o

0

o

5

o

180

o

0

o

0

o

180

o

0

o

*

No

change

in

boiler

temperature

after

reaching

minimum

setpoint

temperature.