Operation, Water temperature max. temp. min. temp – Harman Stove Company PB 105 User Manual

Page 28

Advertising
background image

28

3-90-07205R19_05/13

4.

If Starting After an empty Hopper, Turn Feed

Adjuster to “TeST” (for one 60 second cycle).

This will feed pellets into the auger tube and also
allow you to check the motors for operation.

NOTe:

The auger motor will not operate with any of

the doors open.
5.

Turn Feed Adjuster to #4.

If this is your first fire or you are trying different
pellets, set the feed adjuster to #4, This is an
average number for most pellets and may need
to be adjusted for your particular fuel. After you
know a feed rate setting that works well for your
application, use that setting.
NOTE: You know your feed rate is too high

when: The overheat safety feature is energized

each time the heating zone demand turns off

during a high burn. OR, If unburned or partially

burned pellets are found in the ash pan.(this

may also be an indication of a burn pot in need

of scraping.)

7.

Turn the MAX. TeMP. dial on the control

board to the desired temperature. This setting
must always be at least 5° F. higher than the MIN.
TEMP. setting.

Operation

6.

Flip the Igniter Switch up into the “AUTO”

position.

WARNING: HOT WHIle IN OPeRATION. KeeP

CHIldReN, ClOTHING, ANd FURNITURe

AWAY. CONTACT MAY CAUSe SKIN BURNS.

WATER TEMPERATURE

MAX. TEMP.

MIN. TEMP.

Advertising