Operation – Harman Stove Company PB 105 User Manual

Page 29

Advertising
background image

29

3-90-07205R19_05/13

8.

Turn the MIN. TeMP. dial on the control board to the

desired Minimum temperature. This will start the lighting

process if the temperature at the aquastat sensor is

approximately 5° F. less than the set temperature on

the MAX TEMP. dial.
This is more than just an automatic ignition pellet

boiler. The automatic system will allow the fire size to

be adjusted to match the heating needs and even put

the fire out if necessary. If heat is needed after the fire

is out, the boiler will automatically re-ignite and adjust

the fire size to match the heating need.
9.

Fill hopper with pellets and remove ashes as

required.
Type of Fuel
Use pelletized wood only. The lower the ash content of

the pellets the less cleaning that will be needed of the

heat exchanger surfaces. The cleaner these surfaces

are kept, the more efficient the boiler will be.
NOTE: Do not burn garbage, gasoline, naphtha,

engine oil, or other inappropriate materials in this

unit.
Store pellets in the manufacturer’s wrapping until

needed to prevent pellets from absorbing moisture.

do not store fuel within the appliance installation

clearances, or within the space required for fueling,

ash removal, and other routine maintenance

operations.
lighting A Fire Manually
Lighting the fire manually will not be necessary unless

the igniter system fails.
Follow steps 1 through 5 of the instructions for

automatic lighting.
6.
Flip the Igniter Switch down into the “MANUAL-

LIGHT” position. See Fig. 12.

Operation

7. Open hopper swing plate as shown in Fig. 13 (See

“NOTe” on page 26.)

8. Fill burnpot with pellets as shown. See Fig. 14.

Only fill level with the front edge.

( ------- dO NOT OVeRFIll ------- )

9. Have matches or other ignition source ready.
10. Turn Mode Selector
to desired MIN TEMP setting.

This will start the combustion blower and allow the

ESP to control the fire in relation to the MAX TEMP

Dial setting. (The MAX TEMP dial setting must always

be set above the MIN TEMP setting) Once the fire is

well established the MAX TEMP dial can remain on any

temperature setting desired.
NOTE: When the Switch is set to Manual ignite position

the boiler will function as in auto ignite except the fire

will not be allowed to go out. It will only be allowed to go

to a minimum burn rate between the times the aquastat

is calling for heat. This rate is about 1.1 pound of fuel

per hour. If used in the Manual ignite mode, be sure

there is an overheat dump zone in place. Note that

if the dump zone does not provide sufficient cooling,

and the water temperature continues rising, the feed

motor will be forced to shut off. Because the unit is in

Manual Ignite mode, it will not re-ignite when the water

temperature cools below the control settings.

Fig. 14

Fig. 13

Fig. 12