Frymaster 8195916 User Manual

Page 16

Advertising
background image

3–2

NOTE: On full-pot controllers, only the right set of controls is functional, except that either
ON/OFF switch will turn the controller on or off.

The controller has three error display messages:

, indicating a heating problem. Turn the fryer off and call the Frymaster hotline.

and actual frypot temperature, indicating that the shortening temperature is above 395

°F

(202

°C) [or 410°F (210°C) for CE fryers]. If this display is seen, turn the fryer off immediately and

contact an authorized servicer.

, indicating that the controller has detected a problem in the temperature measuring circuits

and control circuits. Turn the fryer off and contact an authorized servicer.

NOTE: This controller is configured for the fryer on which it installed (i.e., gas or electric and full-
or split-pot). Although identical in appearance, controllers configured for use on one type of fryer
are not interchangeable with those configured for use on another type.

CONTROLLER OPERATING INSTRUCTIONS

1. Turn the controller on. On full-pot units, press either ON/OFF switch

. On split-pot units,

press the left ON/OFF switch

for the left frypot and the right switch for the right frypot.

The controller software version number will display for four seconds then, in non-CE units, the
setpoint temperature will appear in the display. In CE units, the frypot temperature will appear
in the display – to view the setpoint temperature, press the temperature switch

for the frypot

in question (in full-pot units, use the right switch).

A decimal point will appear between the first two numbers of the display, indicating that the unit
is heating. When the frypot has reached the setpoint temperature, the heat indicator decimal
point will go out, indicating that the fryer is ready for cooking.

2. Adjust the setpoint if necessary. To raise the setpoint temperature, press an up arrow

. On

split-pot units, use the left set of controls for the left frypot and the right set of controls for the
right frypot; on full-pot units, use the right set of controls. Press a down arrow

to lower the

setpoint temperature.

The display will change at the rate of approximately one-degree per second initially. If the arrow
is pressed and held, after a change of about 12

°, the rate of change will increase, allowing large

changes in setpoint temperature to be made quickly.

SELECTING FAHRENHEIT OR CELSIUS DISPLAY MODE


To toggle the temperature display between Fahrenheit and Celsius, press the right C/F switch

.

The display(s) will change from xxx

°F to xxx°C, where “xxx” is the frypot or setpoint temperature.

Advertising