Frymaster MASTERJET J1X User Manual

Page 12

Advertising
background image

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS

CHAPTER 2: INSTALLATION INSTRUCTIONS

2-4

2.3 Pre-Connection Preparations (cont.)

2. Refer to the data plate on the inside of the fryer door to verify that the fryer burner is

configured for the proper type of gas before connecting the gas line quick-disconnect device
or piping from the gas supply line.

3. Verify the minimum and maximum gas supply pressures for the type of gas to be used in

accordance with the accompanying tables:


Standard Incoming Gas Pressure

for J1C, J1X, and J2X

Gas

Minimum

(J1C/J1X)

Maximum

(J1C/J1X)

Minimum

(J2X)

Maximum

(J2X)

Natural

6" W.C.
1.5 kPa

15 mbar

14" W.C.
3.49 kPa

34.9 mbar

6" W.C.
1.5 kPa

15 mbar

14" W.C.
3.49 kPa

34.9 mbar

LP

10" W.C.

2.5 kPa

25 mbar

14" W.C.
3.49 kPa

34.9 mbar

11" W.C.
2.74 kPa

27.4 mbar

14" W.C.
3.49 kPa

34.9 mbar


2.4 Connection to Gas Line


DANGER

Before connecting new pipe to this appliance, the pipe must be blown out

thoroughly to remove all foreign material. Foreign material in the burner and gas

controls will cause improper and dangerous operation.

DANGER

When pressure-testing incoming gas supply lines, disconnect the fryer from the gas

line if the test pressure will be ½ PSIG (3.45 kPa, 13.84 inches W.C.) or greater to

avoid damage to the fryer’s gas tubes and gas valve(s).

Advertising
This manual is related to the following products: