CHAPTER 6: OPERATOR TROUBLESHOOTING

6-2

6.3 Troubleshooting Abnormal Burner Operation

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

Main burner will not

come on. Pilot

remains lit.

A. Loose, dirty, or corroded

terminals on gas valve.


B. High resistance in contacts of

thermostat.


C. Thermostat out of calibration.

D. Automatic gas valve defective.

E. Automatic gas valve knob turned

to PILOT position.

A. Clean and tighten terminals on gas

valve and thermostat.


B. Replace thermostat.

C. Calibrate thermostat.

D. Replace gas valve.

E. Turn gas valve knob to ON

position.

Main burner does

not light all the way

around.

A. Rear burner flame deflector

broken off.


B. Burner gas pressure too high or

too low.


C. One or more main burner orifices

clogged.


D. Fryer flue connected directly to

vent hood with a chimney-like
duct.

A. Install new rear burner flame

deflector.


B. Adjust gas pressure.

J1C & J1X:
Natural Gas – 4 in. W.C. (1.0 kPa).
LP Gas – 10.0 in. W.C. (2.50 kPa).

J2X:
Natural Gas – 3 in. W.C. (.75 kPa).
LP Gas – 8.25 in. W.C. (2.0 kPa).


C. Clean burner orifices and blow

out with compressed air.


D. Remove chimney-like duct and

allow for at least 18" (46 cm)
between flue outlet and vent hood
filters.

Fryer is operating

normally, but flames

are rolling out of the

front of the burner.

Obstructed gas valve vent tube.

Shut the fryer down and clean the gas
valve vent tube in accordance with
the instructions on Page 5-3 of this
manual.