J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS

CHAPTER 6: OPERATOR TROUBLESHOOTING

6-3

Flame rolling out

from under fryer.

A. Flue obstructed.

B. Too little make-up air in store.

A. Clean obstruction from flue.

B. Increase make-up air into store.

Main burner

delayed ignition

(when delay is only 2

or 3 seconds).

A. One or more burner flame

deflectors broken off.


B. Pilot flame low – less than 1 inch

(25.4 mm).


C. Pilot flame directed away from

first orifice on main burner.


D. Fryer incoming gas pressure too

low.


E. Fryer incoming gas line too small.

F. One or more burner orifices

clogged.

A. Install new burner flame

deflectors.


B. Adjust pilot flame to 1 ½ inches

(38 mm).


C. Reposition pilot hood to direct

flame toward first burner orifice.


D. Have local gas company raise

incoming gas to the proper
pressure.


E. Replace incoming gas line with

proper size.


F. Clean burner orifices with proper

orifice drill.

Pilot light remains

lit when gas valve is

pushed in, but goes

out when released.

A. Gas valve pilot magnet weak.

B. Pilot generator has low millivolt

output.


C. High-limit thermostat stuck open.

D. Loose, dirty, or corroded high-

limit wires.

A. Replace gas valve.

B. Replace pilot generator.

C. Replace high-limit.

D. Clean/tighten high-limit wires on

the gas valve.

Advertising