Frymaster MASTERJET J1X User Manual

Page 15

Advertising
background image

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS

CHAPTER 2: INSTALLATION INSTRUCTIONS

2-7

2.5 Converting to Another Gas Type


Your fryer is configured at the factory for either natural gas or Propane (LP) gas.

If you desire to switch from one type of gas to another, a gas conversion kit must be installed by
an Authorized Service Agency technician.

DANGER

This appliance was configured at the factory for a specific type of gas. Converting

from one type of gas to another requires the installation of specific gas-conversion

components.


DANGER

Switching to a different type of gas without installing the proper conversion kit may

result in fire! NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT

IS NOT CONFIGURED!

Conversion of this appliance from one type of gas to another should only be

performed by qualified, licensed, and authorized installation or service personnel, as

defined in Section 1.6 of this manual.


Gas Conversion Instructions

(for J1C Fryers only)


For fryers at elevations at or above 5,000 feet (1524 meters), call Frymaster Service (1-
800-551-8633) to determine the components appropriate for your configuration and
altitude. Contact your local ASA to order the components and arrange for installation. For
fryers below 5000 feet (1524 meters), see the kits listed below for conversion. Kits
applicable to non-CE units only.


Natural to Propane

Regulator Conversion Kit: P/N 807-1846
Pilot, regulator conversion kit, and orifices kit: P/N 826-1141 (J1C)


Propane to Natural

Regulator Conversion Kit: P/N 807-1849
Pilot, regulator conversion kit, and orifices kit: P/N 826-1142 (J1C)