J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS

CHAPTER 6: OPERATOR TROUBLESHOOTING

6-4

Pilot outage.

A. Automatic gas valve knob turned

to off position.


B. Low pilot flame.

C. Clogged pilot orifice.

D. Pilot burner clogged around pilot

generator.


E. Pilot flame blowing away from

pilot generator (excessive draft in
kitchen).


F. Pilot generator not inserted fully

into pilot burner.


G. Pilot generator low output.

H. High resistance in high-limit

thermostat contacts.


I. Defective pilot magnet in gas

valve.


J. Corroded connection where pilot

generator connects to gas valve.

A. Turn gas valve to PILOT position,

relight pilot.


B. Adjust pilot flame to 1 ½ inches

(38mm).


C. Remove and clean the pilot

orifice. Reinstall.


D. Remove pilot burner. Clean

burner.


E. Eliminate draft in the kitchen.

F. Reinsert pilot generator into pilot

burner until flame surrounds tip.


G. Replace pilot generator.

H. Replace high-limit thermostat.

I. Replace

gas

valve.


J. Clean

pilot

generator connection

at gas valve.