Generation ii technical reference – Frymaster LOV M3000 User Manual

Page 21

Advertising
background image

LOV

Generation II Technical Reference

20

Loading and Updating Software Procedures

Updating the software takes approximately 20 minutes. To update the software, follow these steps:

1. Switch all computers to

OFF

OFF. Press the TEMP button to check current M3000/MIB/AIF/ATO software

version.

2. Remove the two screws on the left side cover plate of the M3000 board.

3. With the computer folded down, insert the SD card into the slot on the left side of the M3000. The

contacts on the card should face down and the notch should appear on the bottom right (see pictures
below).

4. Once

inserted,

UPGRADE IN PROGRESS

UPGRADE IN PROGRESS appears on the left display and WAIT

WAIT on the right.

5. The display then changes to

CC UPDATING

CC UPDATING on the left and the percentage completed appears on the

right. The display counts up to 100 on the right, changing to a fl ashing

BOOT

BOOT. DO NOT REMOVE

THE CARD UNTIL THE DISPLAY PROMPTS TO DO SO IN STEP 8.

6. Then,

UPGRADE IN PROGRESS

UPGRADE IN PROGRESS is displayed on the left display and WAIT

WAIT on the right again,

followed by

COOK HEX

COOK HEX, mib HEX

mib HEX, aif HEX

aif HEX ending with aTO HEX

aTO HEX displayed on the left and

the percentage complete on the right.

7. The display then changes to

REMOVED SD CARD

REMOVED SD CARD on the left and 100

100 on the right.

8. Remove the SD card using the fi ngernail slot on the top of the SD card.

9. Once the SD card is removed the display changes to

CYCLE POWER

CYCLE POWER.

10. Cycle the control power using the hidden reset switch behind the right control box (see page 38). HOLD

THE SWITCH FOR 10 SECONDS ENSURING THE MIB BOARD HAS POWERED FULLY
DOWN.

11.

M3000 CAN TX FULL

M3000 CAN TX FULL (a SERVICE REQUIRED

SERVICE REQUIRED error) may appear while computers are

rebooting. Press YES at the prompt to cancel alarm. A fl ashing

BOOT

BOOT is displayed on the remaining

computers while the program is transferred.

12. When the update is complete, the M3000 displays

OFF

OFF. The MIB display will remain blank while

software is loading, changing to show the vat numbers. Once the LEDs stop blinking, press

YES

YES to

SYSTEM ERROR FIXED?

SYSTEM ERROR FIXED? Enter 1111. The MIB board will display A.

13. Cycle the control power using the hidden reset switch behind the right control box again. ENSURE

THE SWITCH IS HELD FOR 10 SECONDS. WAIT ANOTHER 20 SECONDS UNTIL THE MIB
BOARD HAS FULLY RESET BEFORE CONTINUING.

14. With the computer displaying

OFF

OFF, VERIFY software update by pressing the TEMP button to check

updated M3000/MIB/AIF/ATO version on each computer. IF ANY BOARDS DID NOT UPDATE,
REPEAT THE PROCESS STARTING WITH STEP 3.