Generation ii technical reference – Frymaster LOV M3000 User Manual

Page 27

Advertising
background image

LOV

Generation II Technical Reference

26

Service Required Errors

A SERVICE REQUIRED

SERVICE REQUIRED error alternating with YES

YES displays on the computer. After YES

YES is

pressed the alarm is silenced. The computer displays an error message from the list below three
times with the location of the error. Then, the computer displays SYSTEM ERROR FIXED?

SYSTEM ERROR FIXED?

YES/NO

YES/NO. If yes

yes is chosen, enter code 1111

1111. If NO

NO is chosen, the system returns to cook

mode for 15 minutes then redisplays error until issue is fi xed.

Pressing the MIB reset button during any fi lter function will generate a

SERVICE RE-

SERVICE RE-

QUIRED

QUIRED error.

This is a list of the service required errors and cause.

ERROR MESSAGE

EXPLANATION

PUMP NOT FILLING

Oil not returning to vat quickly. Possible problems: dirty pad, bad
or missing O-rings, tripped or defective fi lter pump, actuators or
linkage.

DRAIN VALVE NOT OPEN

Drain valve failed to open; the valve’s position is unknown.

DRAIN VALVE NOT CLOSED

Drain valve failed to close; the valve’s position is unknown.

RETURN VALVE NOT OPEN

Return valve failed to open; the valve’s position is unknown.

RETURN VALVE NOT CLOSED

Return valve failed to close; the valve’s position is unknown.

MIB BOARD

Problem with CAN communications; check for loose CAN connec-
tions. MIB board failure.

AIF BOARD

MIB detects AIF missing; AIF board failure.

ATO BOARD

MIB detects ATO board connection lost; ATO board failure.

HIGH LIMIT FAILURE

High limit circuit has an issue.

AIF PROBE

AIF RTD reading out of range.

ATO PROBE

ATO RTD reading out of range.

TEMP PROBE FAILURE

TEMP Probe reading out of range.

MIB SOFTWARE

Internal MIB software error.

INVALID CODE LOCATION

SD card removed during update.

MISCONFIGURED ENERGY
TYPE

Energy type in fryer setup is incorrect; set proper energy type gas
or electric. Press 1234 to enter setup to properly confi gure fryer.

RTC INVALID DATE

The date is invalid. Press 1234 to enter setup to properly confi g-
ure fryer and set proper date.

Advertising