Problem

Probable Causes

Corrective Action

M3000 display shows

RECOVERY FAULT

RECOVERY FAULT

CALL SERVICE.

CALL SERVICE.

Recovery time exceeded maximum
time limit for two or more cycles.

Silence the alarm by pressing the 9
button. Clear the error using the code
on page 25. Maximum recovery for
electric is 1:40.

M3000 display

shows

ENERGY

ENERGY

MISCONFIGURED

MISCONFIGURED

Wrong energy type selected in
setup.

Press 1234 to enter setup and set
energy type for electric.

M3000 display shows

EXCEPTION ERROR

EXCEPTION ERROR

with the description on the

right.

An error has occurred.

Press 1234 to enter setup and
reconfi gure the computer.

M3000 displays

SERVICE

SERVICE

REQUIRED

REQUIRED followed by

the error

.

An error has occurred.

Press YES to silence alarm. The
error is displayed three times. See
list of issues on page 26. Fix issue.
The computer displays SYSTEM

SYSTEM

ERROR FIXED? YES/NO.

ERROR FIXED? YES/NO. Press

YES. Computer displays ENTER

ENTER

CODE

CODE.. Enter 1111 to clear error

code. Pressing NO will allow the fryer
to cook, but error will be redisplayed
every 15 minutes.

M3000 display is in

wrong temperature scale

(Fahrenheit or Celsius).

Incorrect display option
programmed.

See page 28 to change temperature
scale.

M3000 displays

CHANGE

CHANGE

FILTER PAD

FILTER PAD.

Filter error has occurred, fi lter pad
clogged, 24 hour fi lter pad change
prompt has occurred, or change
fi lter pad was ignored on a prior
prompt.

Change the fi lter pad and ensure the
fi lter pan has been removed from the
fryer for a minimum of 30 seconds.
Do NOT ignore CHANGE FILTER

CHANGE FILTER

PAD

PAD prompts.

M3000 display shows

INSERT pan

INSERT pan.

A. Filter pan is not fully inserted into

fryer.

B. Missing fi lter pan magnet.
C. Defective fi lter pan switch.

A. Pull fi lter pan out and fully reinsert

into fryer.

B. Ensure the fi lter pan magnet is in

place and replace if missing.

C. If the fi lter pan magnet is fully

against the switch and computer
continues to display INSERT

INSERT

pan

pan, switch is possibly defective.

M3000 display shows

hot-hi-1

hot-hi-1.

Frypot temperature is more than
410ºF (210ºC) or, in CE countries,
395ºF (202ºC).

This in an indication of a malfunction
in the temperature control circuitry,
including a failure of the high-limit
thermostat.

M3000 display shows

HI-

HI-

LIMIT

LIMIT.

Computer in high-limit test mode.

This is displayed only during a test of
the high-limit circuit and indicates that
the high-limit has opened properly.