LOV

Generation II Technical Reference

25

M3000 Useful Codes

To enter any of the following codes: Press and hold

and

simultaneously for TEN seconds; three

chirps sounds. The computer displays

TECH MODE

TECH MODE. Enter the codes below to perform this function.

0042

0042 Reset RECOVERY FAULT CALL SERVICE

RECOVERY FAULT CALL SERVICE.

1658

1658 Change from F° to C°. The computer displays off

off. Turn the computer on and check

temperature to see the temperature scale. If the desired scale is not displayed, repeat.

3322

3322 Reset Factory Menu. The computer displays COMPLETE

COMPLETE, and then off

off. (NOTE:

This will delete any hand-entered menu items.)

1650

1650 Enter Tech Mode. See page 1-36 to reset passwords and change fi lter pad time.

1212

1212 Switch Between Domestic and International Menu. The computer displays

COMPLETE

COMPLETE, and then off

off. (NOTE: This will delete any hand-entered menu items.)

0469

0469 Reset Filter Stat Data

Filter Stat Data.

The following codes require the removal and reinsertion of the J3 locator plug on the rear of the computer
before entering the code.

1000

1000 Reset CALL TECH

CALL TECH Message. Disconnect board locator plug (J10). Reinsert plug.

Enter

1000

1000. Computer display switches to off

off. Remove and then restore power to the computer

using the 20-pin plug.

9988

9988 Reset BADCRC

BADCRC Message. Disconnect board locator plug (J10). Reinsert plug. Enter

9988

9988. Computer display switches to off

off. Remove and then restore power to the computer using

the 20-pin plug. Replace the computer.

The following codes are entered when prompted to do so or from an energy misconfi gured exception error.

1111

1111 Reset SERVICE REQUIRED

SERVICE REQUIRED Message. Enter this when the issue is fi xed and you

are prompted to enter.

1234

1234 Enter SETUP MODE

SETUP MODE from energy misconfi gured exception error. (This usu-

ally can be done without pressing the fi lter buttons if an error is displayed.)

Passwords

To enter level one, level two passwords – Press and hold the TEMP and INFO buttons simultane-
ously until

level 1

level 1 or level 2

level 2 is displayed. Release the buttons and ENTER

ENTER Code

Code appears.

1234

1234 Fryer Setup, Level One, and Level Two.

4321

4321 – Usage Password.