Generation ii technical reference, Data network flow chart – Frymaster LOV M3000 User Manual

Page 44

Advertising
background image

LOV

Generation II Technical Reference

43

Data Network Flow Chart

Right

M3000

Middle

M3000

Left

M3000

MIB

Left

AIF

Middle

AIF

Right

AIF

ATO

J10

J9

J5

J7

J6

J7

J6

J7

J6

J1

J2

J4

J5

J4

J5

J4

120 Ω Pins 2 & 3

120 Ω Pins 2 & 3

NOTE:

Pins 2 & 3 can

be tested on any plug
throughout the system
and should read 120Ω.

The data network plugs
on the boards can be
swapped. (ie. J4 and
J5 on the AIF board.)

START OF 6-WIRE

DATA AND POWER

(24VDC) HARNESS

3-wire harness

3-wire harness

3-wire harness

6-wire

harness

6-wire harness

3-wire harness

For systems that have a LON Board and/

or 4 or 5 battery systems have an

additional ATO Board.

ATO

J202

J9

120 Ω Pins 2 & 3

6-wire harness

6-wire harness

J10

2

nd

ATO

J9

J10

6-wire harness

LON

J203

2

nd

ATO board only

in 4 and 5 batteries

6-wire

harness

6-wire

harness

6-wire

harness

Oil Level

Sensor

(gas only)

Oil Level

Sensor

(gas only)

Oil Level

Sensor

(gas only)

Turn each computer to OFF. Press the TEMP
button on each computer and verify ALL software
versions are present (M3000, MIB, AIF, ATO and
LON on US only). A missing version may indicate
an open connection. Connections from the MIB to
the AIF boards carry 24VDC on the gray cable.

Advertising