Generation ii technical reference – Frymaster LOV M3000 User Manual

Page 5

Advertising
background image

LOV

Generation II Technical Reference

4

Problem

Probable Causes

Corrective Action

Frypots won’t top off.

A. Probe temperature lower than

setpoint.

B. Oil is too cold.

C. Bad Connection.

D. ATO board power loss.

E. Failed transformer/harness.

F. ATO pump failed.

G. Failed ATO board.

A. Check to see that fryer is heating.

Fryer temperature must be at
setpoint. Check ATO probe
resistance. If probe is bad, replace
the probe.

B. Ensure that the oil in the JIB is

above 70°F (21°C).

C. With the computer OFF, press

TEMP button and ensure the
ATO version appears. If not,
the connection between the AIF
and the ATO board may be bad.
Ensure the 6-pin CAN connectors
are tight between AIF (J4 and J5)
and ATO (J10) boards.

D. Power to the ATO board has been

cut off. Restore power to the board
and clear any service required
errors.

E. Ensure transformer in ATO box is

functioning properly. Check power
from transformer to ATO board.
Ensure all harnesses are plugged
securely into place.

F. Ensure pump is operational.

Check voltage to pump. Replace
the pump if defective.

G. Check for proper voltages using the

pin position charts found on pages
43-47. If ATO found defective,
replace ATO board and clear any
errors.

One vat tops off but other

vats fail to top off.

A. Loose wire connection.

B. Actuator issue.

A. Ensure all wiring harnesses are

securely connected to ATO board
and solenoids.

B. Check return actuator to ensure

actuator is functional.

Incorrect vat tops off.

A. Wired incorrectly.

B. Flexlines connected to wrong vat.

A. Check wiring.
B. Switch fl exlines to correct vat.

One vat doesn’t top off.

A. Filter error exists.

B. Actuator, pump, loose connection,

RTD or ATO issue.

A. Clear fi lter error properly. When

change filter pad YES/

change filter pad YES/
NO

NO is displayed, do NOT press

any button until the pan has been
removed for at least thirty seconds.
After thirty seconds have elapsed,
the computer returns to OFF or last
display.

B. Check actuator, ATO pump, wire

connections, RTD and ATO board.