Generation ii technical reference – Frymaster LOV M3000 User Manual

Page 24

Advertising
background image

LOV

Generation II Technical Reference

23

Problem

Probable Causes

Corrective Action

M3000 display shows

low temp

low temp alternating

with MLT-CYCL

with MLT-CYCL.

Frypot temperature is between
180°F (82°C) and 315°F (157°C).

This display is normal when the fryer
is fi rst turned on while in the melt cycle
mode. To bypass the melt cycle press
and hold either #1 or #2 product button
under the LCD display until a chirp is
heard. The computer displays EXIT

EXIT

MELT

MELT alternating with YES

YES and NO

NO.

Press the #1 YES button to exit melt.
If the display continues, the fryer is not
heating.

M3000 display shows
ERROR RM SDCRD

ERROR RM SDCRD

Defective SD card.

Replace card with another card.

M3000 display shows

TEMP PROBE

TEMP PROBE

FAILURE.

FAILURE.

A. Problem with the temperature

measuring circuitry including the
probe.

B. Damaged computer wiring

harness or connector.

A. This indicates a problem within the

temperature measuring circuitry.
Check resistance of probe, if faulty
replace probe.

B. Swap the computer wiring harness

with one known to be good. If
problem is corrected, replace the
harness.

MAINT FILTER

MAINT FILTER (Manual

Filter) won’t start.

Temperature too low.

Ensure fryer is at setpoint before starting
MAINT FILTER.

MAINT FILTER.

M3000 display shows

REMOVE DISCARD

REMOVE DISCARD.

In non-dedicated mode, a product is
dropped that has a different setpoint
that the current vat temperature.

Remove and discard product. Press a
cook button under the display with the
error to remove the error. Reset the
setpoint of the vat before trying to cook
product.

M3000 display shows

HEATING FAILURE

HEATING FAILURE.

Failed computer, failed interface
board, open high-limit thermostat.

Turn off the vat with the problem. This
error is displayed if the fryer loses its
ability to heat oil. It is also displayed
when the oil temperature is above
450°F (232°C) and the high-limit
thermostat has opened, halting the
heating of the oil.

Computer will not go into

program mode or some

buttons do not actuate.

Failed computer.

Replace computer

M3000 display shows

HI

HI

2 BAD.

2 BAD.

Computer in high-limit test mode.

This is displayed during a test of the
high-limit circuit to indicate if the high-
limit has failed.

M3000 display shows

HELP HI-2

HELP HI-2 or HIGH

HIGH

LIMIT FAILURE

LIMIT FAILURE.

Failed high-limit.

This is displayed to indicate the high-
limit has failed.

Advertising