Adjustment and check, 1 hull unit check – Furuno FSV-84 User Manual
Page 49
3-1
3. ADJUSTMENT
AND
CHECK
3.1 Hull Unit Check
Setting transmission on
Default setting of transmission is OFF. Set the transmission on as follows:
Note: NEVER transmit when the vessel is in drydock.
1. Turn on the power, and then press the [MENU] key to show the main menu.
QUIT
H-SCAN SETTING...
V-SCAN SETTING...
OTHERS...
User Menu
Settings change according
to user preference.
MENU
TX PULSE LENGTH-H : 9
TX POWER-H
: 9
TVG-NEAR-H
: 0
TVG-MEDIUM-H
: 0
TVG-FAR-H
: 0
AGC-H
: 0
2ND AGC-H
: 0
ECHO AVERAGE-H
: 0
COLOR-H
: COLOR 1
COLOR RESPONSE-H : COLOR CURVE 3
Main menu
2. Use the trackball to choose OTHERS and press the [MENU] key.
MENU
QUIT
QUIT
ES1 SETTING...
ES2 SETTING...
ERASE MARKS...
DISPLAY SETTING...
ALARM & AUDIO...
PRESET, MEMORY CARD...
INITIAL SETTING...
OTHERS
OTHERS menu
3. Choose INITIAL SETTING and press the [MENU] key.
CAUTION
THIS ITEM IS DEFINED AS NON-CHANGEABLE ITEM.
ARE YOU SURE TO CHANGE IT TO CHANGEABLE ?
NO
YES